Page 1
CAUTION LASER LIGHT DO NOT STARE INTO BEAM 670nm LASER DIODE,1.0mW MAX OUTPUT IEC 825-1(1993)CLASS I,US 21 CFR 1040 CLASS IIa LASER PRODUCT ZBX99030301 P/N : MUL-53221-04...
Page 2
Hsin-Tien City, Taipei, Taiwan, R.O.C. Hsin-Tien City, Taipei, Taiwan, R.O.C. Tel. +886-2-2218-2018 Tel. +886-2-2218-3501 Fax.+886-2-2218-8670 Fax.+886-2-2218-1415 Web site: www.zebex.com.tw Web site: www.zebex.com.tw E-mail: mail@zebex.com.tw E-mail: mail@zebex.com.tw GERMANY Z E B E X A M E R I C A I N C .
Page 3
NEC is a registered trade mark of NEC Corporation. All other registered trade marks are registered companys' property. ZEBEX is a registered trade mark of ZEBEX INDUSTRIES INC. All rights reserved, reproduction of this document or any portion of its contents is not allowed without the specific...
I M P O R T A N T N O T I C E T A B L E O F C O N T E N T S Introduction ............1 Default Parameters ..........2 Program Procedure ..........5 System Setting............6 Scanning Mode Selection ........7 Header and Trailer...
1. INTRODUCTION Italian Pharmac Parameters Setting....34 ISBN/ ISSN Conversion ........35 The series scanners can be configured by scanning a Wand Emulation Parameters Setting ....36 series of programming bar code labels. This allows Emulation Speed Selection ....... 36 decoding options and interface protocols to be Emulation Data Output Selection....
3. DEFAULT PARAMETERS DEFAULT VALUES OF KEYBOARD EMULATION PARAMETERS SETTING This table gives the default settings of all the programmable parameters. The default settings will Function Default Values be restored whenever the "Reset" programming label Keyboard type selection IBM PC/AT USA is scanned and the laser scanner is in programming Message terminator Enter/ carriage...
DEFAULT VALUES OF DECODING PARAMETERS Note: The configuration of the items with asterisk ( ¡ ° ) is effective when being appointed in advance. Function Code Default Value Code 39 Enable 4. PROGRAM PROCEDURE USING BAR CODE ITF 2 of 5 Enable MENUS Chinese Post Code...
Without any scanning, the unit will enter standby mode. reactivate the unit, present an Start of Configuration object in front of the IR sensor. (*Only for Alpha-60 series.) Object detect Trigger • The reading of the "RESET” label Note: To avoid hazardous exposure, all laser scanner are turns all the parameters back to equipped with an internal cut-off security system default values.
INTER-CHARACTER DELAY This option governs delay time between consecutive characters. The delay time can be altered by Start of Configuration scanning the following labels. HEADER AND TRAILER This option allows you to append a header and/or a trailer to every message transmitted via the serial ports or the None keyboard port.
SOUND DURATION Start of Configuration SEND COMMAND IN BLOCK MODE long(120ms) COMMUNICATION You can use this option to set your own “Send” command used in block mode communication. Medium(50ms) Enable Short(20ms) Disable Very short(5ms) Store BAR CODE IDENTIFIER CODE SELECTION The series RS-232C and keyboard emulation types scanners can transmit max.
Start of Configuration Code 39 BAR CODE IDENTIFIER CODE SETTING The series RS-232C and keyboard emulation type Code 128 scanners can set max. 2 digits of bar code identifier code according to different bar code. The procedure is as following: 1.
Start of Configuration STX/ETX PARITY Even KEYBOARD EMULATION PARAMETERS SETTING KEYBOARD TYPE SELECTION IBM AT Mark PS/2 30-80 Space IBM 5550 MESSAGE TERMINATOR (FOR RS-232C TYPE ONLY) IBM 5295 Terminal None IBM XT CR/LF IBM 3477/3472 Terminal IBM 5530-SC End of Configuration H Tab...
KEYBOARD LANGUAGE SELECTION Start of Configuration KEYBOARD TYPE SELECTION (Cont’d) IBM 5530-ZC Germany NEC 9801 French IBM 3196 Terminal Spainish APPLE MAC II( ¡ ° ) Italian MOS SYS Swiss PS2/30/56 Swedish IBM 3477 Terminal (without break code) End of Configuration NEC 5200( ¡...
FUNTION KEY ACTIVE ON/ OFF (FOR IBM AT USE) Function keys can be concatenated with input data as header and/or trailer. See page 40 table. Start of Configuration MESSAGE TERMINATOR (FOR KEYBOARD WEDGE USE) None CAPITAL LOCK ON/ OFF Select the suitable code to match your keyboard caps Return lock status.
Page 16
Start of Configuration Code 93 Enable RDADING CODE SELECTION (Cont’d) Code 93 Disable UPC/ EAN/ JAN Enable IATA Enable UPC/ EAN/ JAN Disable IATA Disable ITF 2 of 5 Enable EAN- 128 Enable ITF 2 of 5 Disable EAN-128 Disable Chinese post code Enable MATRIX 25 Enable Chinese post code Disable...
INTERLEAVED 2 OF 5 PARAMENTERS SETTING Examples: Felting length 4 to 8 digits Start of Configuration LENTGTH CODE 39 PARAMETERS SETTING Ssan:1. Start of configuration CHARACTER SET Standard Code 39 End of configuration Full ASCII Code 39 START/STOP CHARACTER TRANSMISSION CHECK DIGIT CHECK DIGIT Calculate and Transmit...
Start of Configuration EAN-8 or EAN-13 CHINESE POST CODE PARAMETERS SETTING UPC-A and EAN-13 LENGTH Ssan:1. Start configuration UPC-A and UPC-E UPC-A End of configuration UPC-E CHECK DIGIT EAN-13 EAN-8 ADDENDUM Calculate and Transmit Calculate but not Transmit UPC/EAN/JAN PARAMETERS SETTING 5 Characters FORMAT End of Configuration...
Page 19
TRANSMIT UPC-A CHECK DIGIT Start of Configuration UPC/EAN/JAN PARAMETERS SETTING (Cont’d) 2 Characters TRANSMIT UPC-E LEADING CHARACTER 2 or 5 Characters FORCE UPC-E TO UPC-A FORMAT TRANSMIT UPC-E CHECK DIGIT FORCE UPC-A TO EAN-13 FORMAT TRANSMIT EAN-13 CHECK DIGIT TRANSMIT UPC-A LEADING CHARACTER End of Configuration...
CODE 128 PARAMETERS SETTING FNC 2 CONCATENATION Start of Configuration UPC/EAN/JAN PARAMETERS SETTING (Cont’d) Enable TRANSMIT EAN-8 CHECK DIGIT Disable CHECK DIGIT CODABAR/ MONARCH PARAMETERS SETTING START/ STOP CHARACTER TRANSMISSION Calculate and Transmit Calculate but not Transmit A, B, C, D UCC/EAN128 PARAMETERS SETTING The character FNC1 can be transmitted or not using these codes.
MSI/PLESSY PARAMETERS SETTING (Cont’d) Start of Configuration Calculate but only first one Transmitted MATRIX 25 PARAMETERS SETTING LENGTH Ssan:1. Start Calculated and both Transmitted configuration Single Check digit Calculated but not Transmitted End of configuration Calculated and transmitted Plessy code setting MSI/PLESSY PARAMETERS SETTING Length Calculated and transmitted...
CODE 128 LENGTH SETTING Start of Configuration ITALIAN PHARMAC PARAMETERS SETTING TRANSMIT "A" CHARACTER CODABAR LENGTH SETTING BAR CODE LENGTH SETTING CODE 39 LENGTH SETTING ISBN/ ISSN CONVERSION function convents UPC/EAN codes appearing on books and magazine not ISBN/ISSN CODE 93 LENGTH SETTING format.
WNAD EMULATION NARROW/WIDE RATIO Start of Configuration WAND EMULATION PARAMETERS SETTING EMULATION SPEED SELECTION End of Configuration Medium Normal High Higher EMULATION DATA OUTPUT SELECTION The decoded data output logic level can be set to befit the external decoder. Black = High Black = Low...
FUNCTION KEY EMULATION APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE FUNCTION CODE FUNCTION CODE ASCII ASCII Start of Configuration Home Down Left Backspace (Up) Enter(num) Right PgUp Enter (Ins) PgDn Ctl(L) shift Alt(L) (Down) 5 (num) CURSOR PAD WORK AT NUMLOCK (Del) (Left) (Home)
Page 26
APPENDIX B APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE CODE 39 FULL ASCII BAR CODE TABLE Start of Configuration (F6) (ESC) (Enter)(num) 5 (num) (F7) Ctl (L) (Right) (F1) (F8) Alt (L) (PgUp) (F2) (F9) (Enter) (F10) (F3) (PgDn) (F11) "...
Page 27
APPENDIX B APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE CODE 39 FULL ASCII BAR CODE TABLE Start of Configuration < & > End of Configuration...
Page 28
APPENDIX B APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE CODE 39 FULL ASCII BAR CODE TABLE Start of Configuration End of Configuration...
Page 29
APPENDIX B APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE CODE 39 FULL ASCII BAR CODE TABLE Start of Configuration End of Configuration...
Page 30
APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE Start of Configuration End of Configuration...
Need help?
Do you have a question about the Alpha-50 series and is the answer not in the manual?
Questions and answers