Mechanical Disassembly - Sanyo PLC-WXU700A Service Manual

Hide thumbs Also See for PLC-WXU700A:
Table of Contents

Advertisement

Mechanical Disassembly

Mechanical disassembly should be made following procedures in numerical or-
der.
Following steps show the basic procedures, therefore unnecessary step may
be ignored.
Caution:
The parts and screws should be placed exactly the same position as the original
otherwise it may cause loss of performance and product safety.
z Cabinet Top, Front, R/C Board removal
1. Remove 5 screws A(T3x10) to remove the cabinet top.
. Remove  screws B(M.5X6) and  screws C(T3x8) to
remove the Cabinet front.
3. Remove screw D(M.5x6) and  screws E(Tx6) to
remove the Cabinet front shield.
4. Remove  screws F(Tx8) to remove the
Antenna board.
5. Remove screw G(Tx8) to remove the R/C Board.
Antenna Board
R/C Board
B
G (Tx8)
DEC Inlay LED front
C
Cabinet front
D (M.5x6)
Spacer Lens
F (Tx8)x
F
E (Tx6)X
B (M.5x6)x
C (T3x8)x
A
Decoration LED
E
Cabinet front shield
-13-
S crews Expression
(Type
Diameter x Length
T type
M Type
A (T3x10)x5
Cabinet top
Control Buttons
A
Fig.1
) mm
A
A

Hide quick links: