Electrical Adjustments
Group/
Item Name
Item
0 Fan1 Initial Volt
1 Fan Initial Volt
 Fan3 Initial Volt
3 Fan4 Initial Volt
4 Fan5 Initial Volt
5 Fan6-8 Initial Duty
6 Fan8 Initial Volt
8 Cooling Time L1
9 Cooling Time L
10 Temp Error Cooling Time
11 OnStart Cooling Start Thresh-
old
1 After shutdown cooling
Group
Fan Lamp Voltage down Setting
256
0 Lamp Voltage
1 Lamp Vol Threshold
 Fan1 Speed Gain
3 Fan Speed Gain
4 Fan3 Speed Gain
5 Fan4 Speed Gain
Group
Fan dimmer Setting
257
Dimmer Average Check
0
Period
1 Dimmer Average
 Last Voltage Difference
3 Voltate Difference Goal
Group
Fan IC temp for Netowrk model
258
Standby
Cooling
Check
0
Cycle
Standby
Cooling
Start
1
Threshold
 Standby Cooling Enable
Group
Fan Press Setting
259
0 Press Ssource Range Low
1 Press Ssource Range High
 Press Fan Add Range
High(Lamp In)
3 Press Fan Add Range
Low(Lamp In)
4 Press Fan Add Range
High(No Lamp In)
Press Fan Add Range Low
5
(No Lamp In)
Group
Auto Calibration (Commn) * Auto Calibration
260
0 Execute Calibration
1 Loop Count
 Auto Status
3 AutoWait
4 CHECK -Tolelance
5 Time out wait
Group
Auto Calibration (rGB)
261
0 OFFSET AREA H START
Function
Fan Start Voltage (0.1V)
Fan Voltage at Power Off (0.1V)
Cooling Time stting at Fan Mode L1 (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
Cooling Time stting at Fan Mode L (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
Cooling Time setting at Temp Erro (x
30 sec)
Cooling after shutdown (0: No, 1: Yes)
Current Lamp Voltage (0.1V)(Read
only)
Threshold to judge Lamp Voltage
Down ( V×10)
Additional Fan Speed of Min at Lamp
Voltage Down (unit: 0.1V)
Dimmer Avarage measurement Time
(0:10sec, 1:30sec, :6sec,
90sec...10:300sec)
Dimmer Avarage Value (Read only)
Temp A check cycle at Standby
Cooling start threshold temp A
Cooling in standby Enable
Maximum Execution Times (OFFSET-
>GAIN)
Result of Auto-Calibration (Last
Memory)
Wait Value for each setting
Torelance of OFFSET
Time out waiting time(sec)
Black Level Acquiring Area H-Start
Position
Initial
60
60
60
-
-
-
-
3
4
3
60
1
-
30
0
300
300
300
1
-
-
5
46
1
-
-
-
-
-
-
0
8
0
3
4
0
975
-45-
range
Note
0-145
0-145
0-145
0-55
0-55
0-55
0-55
1-15
1-15
1-15
0-100
0-1
0-55
30-90
0-55
0-55
0-55
0-55
0-10
-
-
0-100
0-100
0-1
0-103
0-103
0-5000
0-5000
0-5000
05000
Executes Auto-Calibration when
0 - 1
changiing the Value (PC White
100%)
1 - 30
0: OK, 1: Adjusting,9: Error *
0 / 1 / 9
ReadOnly
1 - 0
1 - 55
1-55
0 - 1000