Electrical Adjustments
Group/
Item Name
Item
10 Temp A Warning (Eco)
11 Temp B Warning (Eco)
1 Temp C Warning (Eco)
13 Temp B-A Warning (Eco)
14 Temp C-A Warning (Eco)
Temp A Warning Offset
15
(Temp)
Temp B Warning Offset
16
(Temp)
Temp C Warning Offset
17
(Temp)
Temp B-A Warning Offset
18
(Temp)
Temp C-A Warning Offset
19
(Temp)
Temp A Warning Offset
0
(Time)
Temp B Warning Offset
1
(Time)
Temp C Warning Offset

(Time)
Temp B-A Warning Offset
3
(Time)
Temp C-A Warning Offset
4
(Time)
Group
Fan Control range Setting (temp./Voltage)
254
0 High Fan Control Min Temp
1 High Fan Control Max Temp
 High Fan1 Min
3 High Fan1 Max
4 High Fan Min
5 High Fan Max
6 High Fan3 Min
7 High Fan3 Max
8 High Fan4 Min(LAMP1)
9 High Fan4 Max(LAMP1)
10 High Fan5 Min(LAMP1)
11 High Fan4 Max(LAMP1)
1 Normal Fan Control Min Temp
13 Normal Fan Control Max
Temp
14 Normal Fan1 Min
15 Normal Fan1 Max
16 Normal Fan Min
17 Normal Fan Max
18 Normal Fan3 Min
19 Normal Fan3 Max
0 Normal Fan4 Min
1 Normal Fan4 Max
 Normal Fan5 Min
3 Normal Fan5 Max
4 Eco Fan Control Min Temp
5 Eco Fan Control Max Temp
6 Eco Fan1 Min
7 Eco Fan1 Max
8 Eco Fan Min
9 Eco Fan Max
30 Eco Fan3 Min
31 Eco Fan3 Max
3 Eco Fan4 Min(LAMP1)
33 Eco Fan4 Max(LAMP1)
34 Eco Fan5 Min(LAMP1)
35 Eco Fan5 Max(LAMP1)
Group
Fan Start/Cooling Setting
255
Function
Temp. A to judge the Temp Error at
Eco (Room)
Temp. B to judge the Temp Error at
Eco (Panel)
Temp. C to judge the Temp Error at
Eco (Lamp)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Offset of Temp Error (Minutes)
Error Setting Value is increased X min-
ute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Temp Senser Control Start/End Temp.
at High
Fan voltage value at High (unit: 0.1V)
Temp Senser Control Start/End Tem.p
at Normal
Fan voltage value at Normal (unit:
0.1V)
Temp Senser Control Start/End Tem.p
at Eco
Fan voltage value at Eco (unit: 0.1V)
Initial
46
46
6
6
60
60
100
100
100
100
5
15
15
100
100
15
30
30
40
40
Normal
Ceiling
38
38
4
4
95
95
135
135
85
85
130
130
75
75
77
77
-
-
-
-
-
-
-
-
38
38
4
4
80
80
15
15
75
75
80
10
70
70
70
70
-
-
-
-
-
-
-
-
36
36
4
4
65
65
115
115
70
70
110
110
53
53
53
53
-
-
-
-
-
-
-
-
-44-
range
Note
30-100
30-100
30-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-100
0-100
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-100
0-100
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55