Mechanical Disassembly
x Main Board, AV Board, Rear Panel and Fans removal
1. Remove 6 screws A(M.5x6),screw B(M.5x6) and C(M4x4)to remove the Main board.
. Remove  screws D(T3x6) to remove the AV board and the Rear panel.
3. Remove screw E(M.5x6) to remove the Optical top shield.
4. Remove screw F to remove fans (FN901, FN90) and the Side grill.
A (M.5x6)x5
AV board
c Fan (FN907) removal
1. D isconnect the lamp ballast socket.
. Remove screw A(T3x8) and B(M3x8)
to remove fan (FN907)
Main board
A
D (T3x6)(Black)x
A
A
A
E(M.5x6)
Optical
top shield
A (T3x8)
Trigger
B (M3x8)
Rear panel
D
B (M.5x6)
C (M4x4)
F (T3x6)x
F
FN90
FN907
Trigger
Ballast
socket
* T rigger should be mounted as
the figure above.
Fig.3
-14-
FN901
Side grill
Fig.2
Duct