Setting The Address (Id) Of The Camera; Setting The Protocol Of The Camera - Bosch VEZ-400 Series Operation Manual

Autdome 4000 mini ptz
Hide thumbs Also See for VEZ-400 Series:
Table of Contents

Advertisement

AUTDOME 4000 Mini
PTZ Dome
6.5.1

Setting the address (ID) of the camera

To prevent faulty operations and malfunctions, each camera
must have an unique address (ID). The default setting is
0[ID001].
X0
SW30
1
Table 6.5: Dome Camera ID Setting (Rotary Switches SW301, SW302)
6.5.2

Setting the protocol of the camera

Set the protocol setting, the baud rate, and the termination
setting of dip switch SW303, using the data in the tables below.
Note: The value marked * is the default setting.
No
1
Off On Bosch OSRD*
Off Off Pelco-D/Pelco-
Table 6.6: Camera Protocol Setting (No. 1 & 2, Dip Switch SW303)
No
3
Off Off 2400
Off On 4800
On Off 9600*
On On 38400
Table 6.7: Camera Baud Rate Setting (No. 3 & 4, Dip Switch SW303)
Bosch Security Systems, Inc.
X1
SW30
2
No
Protocol
2
P
No
Baud Rate
4
(bps)
Connection | en