Alternate Upflow Filter Clip / Bracket Installation - Trane UD1A040A9H21B Installation Manual

High efficiency single stage upflow/ horizontal and downflow/ horizontal gas-fired furnaces, “fan assisted combustion system”
Table of Contents

Advertisement

i
Furnace
Cabinet
Side
Engagement Hole
For
Filter Rack
Installation With
Bottom Return
o
Furnace
Cabinet
Side
Engagement Hole
For
Filter Rack
Installation With
Bottom Return
p
BLOWER
DECK
Furnace
Cabinet
Side
18-CD21D1-5
Filter
Rack
Filter Rack
Retaining
Screw/Pin
Filter Rack
Retaining
Screw/Pin
Filter
Rack
Bottom Panel
Furnace
Engagement Hole
Blower
For
Filter Rack
Installation With
Deck
Side
Return
Filter
Filter Rack
Rack
Retaining
Assembly
Screw/Pin
Installer's Guide
a
s
Optional door kit
BAYFLTR206
RETURN AIR FILTERS FOR UPFLOW FURNACE IN
HORIZONTAL CONFIGURATION
When the Upflow Furnace is installed in the horizontal
configuration, the return air filters must be installed
exterior to the furnace cabinet. Remote filter grilles
may be used for homeowner convenience or the filters
may be installed in the duct work upstream of the fur-
nace. See Figure 17.
ALTERNATE UPFLOW FILTER CLIP/ BRACKET INSTAL-
LATION - KIT09224
1.Determine the location to be used. The furnace
cabinet has dimples for location of the alternate fur-
nace clips (Side return only). Pre-drill clearance
holes with a 3/16" drill. Bottom return holes are
pre-drilled. See Figure 21.
2.Install the clips in front and rear of the desired loca-
tion using the screws provided. The filter clip with
the leaf spring mounts in the rear of the cabinet.
TYPICAL DOWNFLOW FURNACE RETURN AIR FILTER
INSTALLATIONS
These furnaces require high velocity type air filters.
Downflow furnace filters must be located outside the
furnace cabinet. Typical installations are shown in Fig-
ure 22. Tables 5 and 6 provide information for installa-
tion of the filter retaining brackets shipped with down-
flow furnaces.
ALTERNATE FILTER
CLIPS LOCATION
13