Lighting Instructions - Trane UD1A040A9H21B Installation Manual

High efficiency single stage upflow/ horizontal and downflow/ horizontal gas-fired furnaces, “fan assisted combustion system”
Table of Contents

Advertisement

Installer's Guide
TABLE 12
GAS FLOW IN CUBIC FEET PER HOUR
2 CUBIC FOOT DIAL
SEC. FLOW SEC. FLOW SEC. FLOW SEC. FLOW
8
900
29
248
9
800
30
240
10
720
31
232
11
655
32
225
12
600
33
218
13
555
34
212
14
514
35
206
15
480
36
200
16
450
37
195
17
424
38
189
18
400
39
185
19
379
40
180
20
360
41
176
21
343
42
172
22
327
43
167
23
313
44
164
24
300
45
160
25
288
46
157
26
277
47
153
27
267
48
150
28
257
49
147
g
Outlet Pressure Boss
Inlet Pressure
Boss (opt.)
On/Off Switch
White-Rodgers 36G gas valve
h
On/Off ff Swi
Switch
White-Rodgers 36F gas valve
22
50
144
82
51
141
84
52
138
86
53
136
88
54
133
90
55
131
92
56
129
94
57
126
96
58
124
98
59
122
100
60
120
104
62
116
108
64
112
112
66
109
116
68
106
120
70
103
124
72
100
128
74
97
132
76
95
136
78
92
140
80
90
144
Regulator
Adjustment
ch
Orifice
Twist Drill
Size If
and Orifice Required At Other Elevations
88
Installed
At Sea
86
Level
84
2000 3000 4000 5000 6000 7000 8000 9000 10000
82
42
42
80
43
44
78
44
45
45
46
76
46
47
75
47
48
73
54
54
72
55
55
69
56
56
67
57
58
64
58
59
62
From National Fuel Gas Code - Table F-4
60

LIGHTING INSTRUCTIONS

58
56
54
DO NOT attempt to manually light the burner.
53
Failure to follow this warning could result in property
51
damage, personal injury or death.
50
Lighting instructions appear on each unit. Each
installation must be checked out at the time of
initial start up to insure proper operation of all
components. Check out should include putting
the unit through one complete cycle as outlined
below.
Turn on the main electrical supply and set the thermo-
stat above the indicated temperature. The ignitor will
automatically heat, then the gas valve is energized to
permit the flow of gas to the burners. After ignition and
flame is established, the flame control module monitors
the flame and supplies power to the gas valve until the
thermostat is satisfied.
TO SHUT OFF
For complete shutdown: Move the control switch on the
main gas valve to the "OFF" position (See Figures 25
and 26). Disconnect the electrical supply to the unit.
If this is done during the cold weather months, provi-
sions must be taken to prevent freeze-up of all water
pipes and water receptacles.
Failure to follow this warning could result in property
damage.
Whenever your house is to be vacant, arrange to
have someone inspect your house for proper tem-
perature. This is very important in below freez-
ing weather. If for any reason your furnace
should fail to operate damage could result, such
as frozen water pipes.
TABLE 13
ALTITUDE ABOVE SEA LEVEL
43
43
43
44
44
44
44
45
45
46
45
45
46
47
47
47
47
47
48
48
47
47
48
48
49
48
49
49
49
50
55
55
55
55
55
55
55
56
56
56
56
57
57
57
58
59
59
60
60
61
60
60
61
62
62
WARNING
!
CAUTION
!
45
46
47
47
47
48
48
48
50
49
49
50
49
50
51
50
51
52
56
56
56
56
56
57
59
59
60
62
63
63
63
63
64
18-CD21D1-5

Advertisement

Table of Contents
loading

Table of Contents