Kenmore 134313400 Use And Care Manual page 6

Coin- operated commercial ryer
Table of Contents

Advertisement

DO NOTINSTALL YOUR DRYER:
1. in an area exposed to dripping water or outside weather
conditions.
2. In an area where it will come in contact with curtains, drapes,
or anything that will obstruct the flow of combustion and
ventilation air.
3. On carpet. Floor MUSTbe solid with a maximum slope of 1
inch (2.54 cm).
iNSTALLATION iN RECESSOR CLOSET
1. A dryer installed in a bedroom, bathroom, recess or closet,
MUSTbe exhausted outdoors.
2. No other fuel burning appliance shall be installed in the
same closet as the Gas dryer.
3. Your dryer needs the space around it for proper ventilation.
DO NOT INSTALL YOUR DRYER iN A CLOSET WITH A
SOLID DOOR.
4. A minimum of 120 square inches (774.2 square cm) of
opening, equally divided at the top and bottom of the door,
is required. Air openings are required to be unobstructed
when a door is installed. A Iouvered door with equivalent
air openings for the full length of the door is acceptable.
MINIMUM INSTALLATION CLEARANCES (inches)
FRONT
SIDES
REAR
TOP
Alcove
0 (0 cm)
0 (0 cm) 0 (0 cm) 15 (38.1 cm)
Closet
1 (2.54 cm) 0 (0 cm) 0 (0 cm) 15 (38.1 cm)
Closet door ventilation required: 2 Iouvered openings each 60
square inches (387 square centimeters) -- 3 inches (7.6 cm)
from bottom and top of door.
THIS DRYERMUST BE EXHAUSTED OUTDOORS.
5. The following
illustrations
show minimum
clearance
dimensions for proper operation
in a recess or closet
installation.
-t- 0 so.,..
CLOSET DOOR
1" (2.54 cm)
i
DON'T-
J_
L
DONIT-\
.....
Incorrect
DON'T
Rigid
Metal
Only
("_'\ ;
----
L
Correct
Correct