® Coin- Operated Commercial Dryer Installation Instructions and Use and Care Guide Models: 64182, 74182 P/N 134313400D (0712) Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. www.sears.com...
For Sears warranty information or to contact a Sears Service Pre-Installation Requirements.........2 Center, call 1-800-4-my-HOME (1-800-469-4663) Electrical Requirements..........3 Exhaust System Requirements......3-4 If you need SERVICE or PARTS for your Kenmore Gas Supply Requirements........4 coin-operated washer: be ready to give the model Rough-In Dimensions..........5 number, serial number and date of purchase.
ELECTRICAL REQUIREMENTS EXHAUST SYSTEM REQUIREMENTS Use only 4 inch (10.2 cm) diameter (minimum) rigid or flexible ELECTRIC Dryer metal duct and approved vent hood which has a swing-out damper(s) that open when the dryer is in operation. When the CIRCUIT - Individual 30 amp. branch circuit fused with 30 amp. dryer stops, the dampers automatically close to prevent drafts time delay fuses or circuit breakers.
than 0.75 inches of water column, the system is acceptable. Exceeding the length of duct pipe or number If the manometer reading is higher than 0.75 inches of water of elbows allowed in the "MAXIMUM LENGTH" charts can column, the system is too restrictive and the installation is cause an accumulation of lint in the exhaust system.
UNPACKING ROUGH-IN DIMENSIONS 1. Using the four shipping carton corner posts (two on each side), carefully lay the dryer on its left side and remove foam shipping base. (68.3 cm) To prevent damage, do not use the control panel 3/8" or coin meter housing as a means to pick up or move the dryer.
DO NOT INSTALL YOUR DRYER: 4. A minimum of 120 square inches (774.2 square cm) of 1. In an area exposed to dripping water or outside weather opening, equally divided at the top and bottom of the door, is required. Air openings are required to be unobstructed conditions.
GROUNDING REQUIREMENTS ELECTRICAL INSTALLATION ELECTRIC Dryer Before proceeding with electrical installation, install the dryer's coin-metering system (when used) in accordance DANGER Improper connection of the equipment with the separate instructions provided with the meter. grounding conductor can result in a risk of electrical shock. Check with a licensed electrician if you are in doubt as to whether the ALL ELECTRIC Dryers appliance is properly grounded.
ELECTRICAL CONNECTIONS ELECTRICAL CONNECTIONS FOR 4-WIRE SYSTEM FOR 3-WIRE SYSTEM ELECTRIC Dryer ELECTRIC Dryer 1. Remove the screws securing the terminal block access cover 1. Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of and the strain relief mounting bracket located on the back of the dryer upper corner.
Lint Blade Retaining Pin Location and Orientation INSTALLATION 1. GAS CONNECTION (Gas dryers only) a. Remove the shipping cap from gas pipe at the rear of the dryer. NOTE: DO NOT connect the dryer to L.P. gas service without converting the gas valve. An L.P. conversion kit must be installed by a qualified gas technician.
Page 10
Timing Cam Pin Chart REPLACING NYLON TIMING CAMS ON ACCUMULATOR MECHANISM TIME PER NUMBER TIME PER NUMBER COIN INSERTED OF PINS COIN INSERTED OF PINS Electrical Shock Hazard 25.7 180 minutes • Disconnect both power supply cords from the electric 22.5 power supply before making these changes.
Page 11
• Pull coin slide out of coin chute (see FIGURE 4). STEP 6 Set new vend price by adding or removing the appropriate block-out keys and/or dime inserts according to th Table of Vend Prices (see FIGURE 7). NOTE: Black colored slots are closed off by block-out key.
To remove block-out keys, pull straight up. STEP 7 Replace coin receiver block into slide: NOTE: Be sure block-out keys and /or dime inserts are seated • Hold coin receiver right side up in the palm of one hand. properly and ratchet dog is in place with irs spring connected (see FIGURE 8).
Meter Case Parts List Parts List For Greenwald Dryer Timers Timer Assembly Timer Assembly Model 50-1232-9 Model 50-1223-10 ITEM PART NUMBER DESCRIPTION 50-61-13-2 Timing motor, 115VAC, 1/180RPM 51-161-4 Timing cam, 4-PIN (45 Minutes)* 00-6164 Switch *Additional 51-161-1 Timing cam,1-PIN (180 Minutes) cams that 51-161-2 Timing cam,2-PIN (90 Minutes)
NEW VEND PRICE ____________________________________________________________ Order required parts using this tear-off. Block-out keys will be shipped to you at no charge. Follow product information Order Form instructions. To change vend price, detach and mail the lower portion to: Customer Service Department Quantity____________________________________________________ Greenwald Industries Inc.
Get it fixed, at your home or ours! Your Home For expert troubleshooting and home solutions advice: www.managemyhome.com For repair – in your home – of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner’s manuals that you need to do-it-yourself.