7. Address Switch

7-1. Address Setting of the Remote Control Unit

The address can be set in order to prevent interference between remote con-
trollers when 2 indoor units are installed near each other. The address is nor-
mally set to "A." To set a different address, it is necessary to change the
address on the second remote controller.
NOTE
Once changed, you cannot restore the original address setting of the air con-
ditioner.
(1) Switch on the power source.
(2) Break the address-setting tab marked "A" on the second remote controller
to change the address (Fig. 62). When the tab is removed, the address is
automatically set to B (Fig. 63).
(3) (SAP-KMRV74EH, KMRV94EH, KMRV124EH, KRV184EH, KRV244EH)
Press and hold the remote controller ION button and 1HR. TIMER button.
Then, press and hold the ACL (Reset) button with a pointed object such
as the tip of a pen. After 5 seconds, release the ACL button first, then
release the ION and 1HR. TIMER buttons. "oP-1" (Test Run) appears,
blinking in the remote controller clock display area.
(SAP-KMRV76EH, KMRV96EH, KMRV126EH, KRV96EHDS, KRV186EH, KRV246EH)
Press and hold the remote controller QUIET button and 1HR. TIMER button. Then, press and hold the ACL (Reset)
button with a pointed object such as the tip of a pen. After 5 seconds, release the ACL button first, then release the
QUIET and 1HR. TIMER buttons. "oP-1" (Test Run) appears, blinking in the remote controller clock display area.
(4) Each time the 1HR. TIMER button is pressed,
the display changes as shown below.
Press this button 2 times to change the
display to "oP-7" (address setting).
(Fig. 64a or 64b)
Test run mode
Selfdiagnostic mode
Address setting mode
(5) "oP-7" has now been selected for address
setting.
(6) Press the ON/OFF operation button on the
remote controller. (Fig. 64a or 64b) Check
that the "beep"signal-received sound is heard
from the second indoor unit (approximately
5 times). The sound you hear is the signal
that the remote controller address has been
changed.
(7) Finally press the remote controller ACL (Reset)
button to cancel the blinking "oP-7" display.
(Fig. 64a or 64b)
Changing of the second remote controller address
is now completed.
2/6/08
1:31 PM
Page 23
ADDRESS
(SAP-KMRV74, KMRV94, KMRV124,
KRV184, KRV244)
ION
button
ACL (Reset)
button
Fig. 64a
23
Tab
Fig. 62
Fig. 63
(SAP-KMRV76, KMRV96,
KMRV126, KRV96,
KRV186, KRV246)
ON/OFF
operation
button
1HR.TIMER
button
QUIET
button
Fig. 64b
ACL button
ON/OFF
operation
button
1HR.
TIMER
button
ACL
(Reset)
button

Advertisement

Table of Contents
loading

Table of Contents