FIGURE 32B - INTEGRATED FURNACE IGNITION CONTROL - PSC
FAULT CODE
BUTTON
THERMOSTAT
TERMINALS
14.2 FURNACE CONNECTION
The furnace is shipped fully wired except for the connections to the house wiring. The furnace power
connections are made in a junction box inside the blower compartment. The junction box contains a BLACK
wire to be connected with L1 (hot), a WHITE wire to be connected with L2 (Neutral), and a GREEN wire to be
connected to the ground.
NOTE
Use good quality wire nuts such as Marrette®
connectors, Ideal® wire nuts, etc.
If the junction box must be moved from it's original location to the other side of the unit.
1. Remove the appropriate plastic cap from the desired left or right side panel, and place it on the panel not
being serviced.
2. Fasten the junction box to the selected panel.
3. Secure power line connection into junction box, following above reference.
4. Use only ground screws for junction enclosure.
THIS FURNACE IS EQUIPPED WITH A BLOWER DOOR SAFETY SWITCH. DO NOT
DISABLE THIS SWITCH. FAILURE TO FOLLOW THIS WARNING CAN RESULT IN
ELECTRICAL SHOCK, PERSONAL INJURY, OR LOSS OF LIFE.
STATUS LED
24 VAC MOLEX
3A FUSE
WARNING
!
120 VAC MOTOR
TERMINALS
ELECTRONIC
AIR CLEANER
TERMINAL
POWER
HUMIDIFIER
TERMINAL
120 VAC NEUTRAL
CONNECTIONS
120 VAC MOLEX
IMPORTANT:
USE COPPER CONDUCTORS ONLY.
H19.2
!
H3.23
41
IOM
W415-0973 / B / 08.28.13