About the alarm action
These are the descriptions of how to perform the settings and confirm the alarm action from a PC.
Refer to the provided operating instructions for further information about the alarm action available in this unit.
• Display the alarm notification window.
• Display the [ALARM RESET] button in the status display area.
• Notifies of an event occurrence by sending e-mails.
When an event occurs, this unit notifies of the event occurrence with the time and date of the event occurrence
by sending e-mails (alarm mails) to the registered addresses. It is also possible to attach an image to the alarm
mail. When the event recording of two or more camera channels is performed, the recorded image from the cam-
era of the lowest camera channel number will be attached.
Up to 4 addresses can be registered as recipients of the alarm mail.
To send the alarm mail at an event occurrence, it is required to perform the settings on the SETUP MENU in
advance. Refer to a system administrator for further information.
It is possible to edit the contents of the alarm mail.
Refer to page 73 for further information about the alarm mail.
• Transmits recorded images to an FTP server at an event occurrence
When an event occurs, recorded images will be continued transmitting to an FTP server automatically for the set
duration from the recording start time. To transmit images automatically, it is necessary to perform the settings
on the SETUP MENU in advance. Refer to a system administrator for further information.
Note:
Images to be transmitted automatically to an FTP server are images recorded during the set duration, starting
from the start time of event recording (event occurrence time). When events occur sequentially, only images
recorded for the set duration, starting from the recording start time of the first event, will be transmitted.
Note:
The alarm notification window will not be displayed
when "ON" is set for "Alarm Suspension", or when
"ACT DET" is selected for "Operation Mode" (event
action mode).
[ALARM RESET] button