boilermate Heating/Hot water controls
The current BoilerMate SP Sol incorporates separate heating/hot water and solar
control systems.
label 1 - Channel 1 of this digital clock is dedicated to the gas boiler control. This can
be set to hold off the boiler during high solar gain periods eg 10.00 am to 16.00 pm
allowing maximum solar contribution.
label 2 - This switch must be left in the ON postion, and should only be used to reset
the solar controller, or to carry out maintenance work on the solar circuit.
The BoilerMate SP Sol heating and hot water controls operate in the same way as the
basic BoilerMate appliances but the single channel clock and the two rocker switches
have been replaced by a two channel digital clock. (Channel 1 controls the gas boiler
/hot water and Channel 2 the heating) and a summer/winter rocker switch has been
added. Details of how to set the clock are shown on a separate manufacturers leaflet
provided with the appliance. Recommendations regarding the setting of Channel
1 and the operation of the summer/winter rocker switch are provided on the labels
adjacent to the controls. Channel 2 should be set as normal to control the heating
on/off times required.
If a high hot water demand is expected or the appliance runs out of hot water the
setting of Channel 1 can be overridden which will bring on the boiler and ensure hot
water is made available.
A-CLASS SP Solar
BoilerMate
OFF:
SLOW FLASHING
MEDIUM FLASHING
RAPID FLASHING
ON:
PUSH BUTTON
Mode
Normal
0
Label 1
Digital
Clock
Normal
Switch failure
Switch backup selected
Overheat safety trip
Switch on
To reset appliance
Control circuit power
Switch
supply
- see above
SOLAR CONTROLLER POWER
OFF
Label 2
2.0 installation
2.2 controls
The Switch 6kW electrical emergency back
up system is fitted to this appliance. This is
switched on by moving the 'mode' rocker
switch from normal to switch and is used in
the event of boiler failure. It is unlikely to be
needed in Summer but can be used in Winter
as required to provide some heating and hot
water in conjunction with the solar input until
the problem can be resolved.
It is an emergency only system and must not be
used if the main system is working correctly.
Red LED
Black button
Green rocker switch
(illuminated when on)
ON
- see above