SECTION 5

5-1 PREPARATION

REQUIRED TEST EQUIPMENTS
When adjusting IC-M34, the optional CS-M34 ADJ
478U/UC (USB type)
CLONING CABLE
EQUIPMENT
Measuring range
Frequency range
RF power meter
(terminated type)
Impedance
SWR
Frequency range
Frequency counter
Frequency accuracy : ±1 ppm or better
Sensitivity
Frequency range
Audio generator
Output level
Impedance
▄ SYSTEM REQUIREMENTS (for
®
®
• Microsoft
Windows
98/98SE/Me/2000/XP
• RS-232C serial port (D-sub 9 pin) or USB port
▄ ADJUSTMENT SOFTWARE INSTALLATION
q Quit all applications when Windows is running.
w Insert the CD into the appropriate CD drive.
e Doublelick the "Setup.exe" contained in the 'CS-M34 ADJ' folder in the CD drive.
r The "Welcome to the InstallShield Wizard for CS-M34 ADJ" will appear. Click [Next>].
t The "Choose Destination Location" will appear. Then click [Next>]
to install the software to the destination folder. (e.g. C:\Program Files\Icom\CS-M34 ADJ)
y After the installation is completed, the "InstallShield Wizard Complete" will appear. Then click [Finish].
u Eject the CD.
i Program group 'CS-M34 ADJ' appears in the 'Programs' folder of the start menu,
and 'CS-M34 ADJ' icon appears on the desk top screen.
STARTING SOFTWARE ADJUSTMENT
(1) Connect IC-M34 and a PC with OPC-478/UC, OPC-1668 and JIG CABLE.
(2) Turn the transceiver ON.
®
(3) Boot up Windows
, and click the program group 'CS-M34 ADJ' in the 'Programs' folder of the [Start] menu,
then CS-M34 ADJ's window appears.
(4) Click 'Adjust' on the CS-M34's window, then IC-M34's up-to-date condition appears.
(5) Set or modify adjustment value as specified.
Microsoft and Windows are registered trademarks of
Microsoft Corporation in the U.S.A. and other countries.
ADJUSTMENT PROCEDURE
ADJUSTMENT SOFTWARE
and a JIG cable (modified OPC-1668, see page 5-2) are required.
GRADE AND RANGE
: 0.1–10 W
: 100–300 MHz
: 50 Ω
: Less than 1.2 : 1
: 0.1–300 MHz
: 100 mV or better
: 300–3000 Hz
: 1–500 mV
: 600 Ω
CS-M34 ADJ
ADJUSTMENT SOFTWARE
(Rev. 1.0 or later), OPC-478 (RS-232C type) or OPC-
EQUIPMENT
Standard signal
generator (SSG)
FM deviation meter
External speaker
Attenuator
)
5 - 1
GRADE AND RANGE
Frequency range : 0.1–300 MHz
: 0.1 µV to 32 mV
Output level
(–127 to –17 dBm)
Frequency range : 30–300 MHz
Measuring range : 0 to ±10 kHz
Input impedance : 8 Ω
Capacity
: More than 1 W
Power attenuation : 30 dB
Capacity
: More than 10 W

Hide quick links: