Maintenance; Stop The Generator - Hyundai DHY12000SE(-3) User Manual

Diesel power generators
Table of Contents

Advertisement

5.

STOP THE GENERATOR

5.1 Stop the generator
1 Before stopping the generator stop any machine connected.
2 Move the thermal of 30mA leakage breaker to the lower position
so the generator is not giving power.
3 Let the generator run for at least 3 min. without load in orther to
cool it down.
4 Stop the generator
- Electric start: Turn the key to the off position
- Remote control: Push the lock open key on the remote
controller.
6.

MAINTENANCE

6.1 Maintenance at fixed period
For the generator to work in conditions, maintenance at fixed
period is very important. The diesel generator is consisted of
diesel engine, alternator, control panel, frame etc.
Before maintaining the generator, stop the engine. You should
perform the maintenance in a well ventilated area
After stopping the generator, clean it immediately to prevent the
corrosion and to remove the sediment.
ITEM
Check the
fuel
Clean fuel
tank
Check oil
leakage
Check each
fastening
Change lube
oil
Clean the element
of air cleaner
Clean fuel
filter
Check fuel
pump
Check the
injector
Check fuel
pipe
Adjust intake/
exhaust valve clearance
Grind intake/
exhaust valve
Change piston
ring
Check battery
voltage
everyday
at 20h
(
first time)
(next 3 times)
shorter the time in dusty enviroments
(first time)
EVERY MONTH
15
every
every
every
100h
200h
500h
(replace)
(change if need)
every year
or 1000h

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dhy15000se(-3)

Table of Contents