Integrated VFD / LCM Installation

1. Remove the VFD Plastic
cover from the terminal
2. Connect the COM 3
internal cable between
Terminal and VFD / LCM
Module and install the
VFD/ LCM module with
Terminal. Fasten one
screw back and make sure
VFD/LCM module is fixed.
3. VFD is connected to the COM3 (COM3 has internal power which has been pre-set as
12V power)
** Please note When VFD/LCM is integrated, please remove the device which connects
to the external COM3 on Rear IO panel to prevent I/O interrupt.
4. Adjust the VFD / LCM
angle into proper position.
AerPOS Series AP-3615