Technical Specification - Heatrae Sadia Amptec 95 022 001 C-400 Fitting Instructions And User Manual

Amptec electic flow boiler
Table of Contents

Advertisement

DESCRIPTION
The AMPTEC electric flow boiler is designed to heat re-circulated water used in wet central heating systems.
The water is heated when it is passed over electric immersion elements, which are contained in a chamber.
The temperature of the water is monitored and controlled by a modulation technique switching on the immersion
elements. The switching of the elements is carried out by solid-state technology contained in the control section
of the boiler. The operation of the boiler can be controlled by standard programmers, room thermostats, etc.
The pump should be connected to the boiler control, which provides the run-on facility.
FEATURES
·
Electric flow boiler for wet central heating systems.
·
Domestic hot water is available from a cylinder.
·
Can be used in a sealed or open vented system installations.
·
No flue or fuel tank required.
·
Quiet in operation.
·
Operates from standard programmers, room thermostats, etc.
·
Pump run-on facility.
·
Solid-state technology enables zero volt switching.
·
Soft start and soft modulation.
·
Front panel operation indicators.
·
User adjustment of the operating temperature on the front panel.
·
Self check every time it operates.
·
Optical isolation to enable connection of more boilers on single or three phase supplies.
·
Electrical tails terminations inside the boiler.
·
Safety trip for no water or no flow situations.

TECHNICAL SPECIFICATION

Output Temperature Control Range:
Operating voltage
Pump supply fuse (internal)
‘RUN’ control input signal requires
‘RUN’ control input signal draws less than 0.25A.
Optical isolation
Over temperature trips
Water content
Product code
Boiler type
95 022 001
C400
95 022 101
U401
95 022 002
C600
95 022 102
U601
95 022 003
C900
95 022 103
U901
95 022 004
C1100
95 022 104
U1101
95 022 005
C1200
95 022 105
U1201
(C series)
(U Series)
220V / Btu
3.5kW / 11,900Btu
3.5kW / 11,900Btu
5kW / 17,000Btu
5kW / 17,000Btu
7.5kW / 25,600Btu
7.5kW / 25,600Btu
9kW / 30,700Btu
9kW / 30,700Btu
10kW / 34,000Btu
10kW / 34,000Btu
65
C to 80
C.
0
0
30
C to 60
C
0
0
200V - 245V 50Hz
T 2A 240V - 20x5mm.
  200V - 245V 50Hz
10mA typical.
Between the control signals
and the boiler supply.
95 and 100
C
0
1.3 litres
240V / Btu
4kW / 13,600Btu
4kW / 13,600Btu
6kW / 20,400Btu
6kW / 20,400Btu
9kW / 30,700Btu
9kW / 30,700Btu
11kW / 37,500Btu
1kW / 37,500Btu
12kW / 40,900Btu
12kW / 40,900Btu
Size
1050 x 90 x 90mm
1050 x 90 x 90mm
1050 x 90 x 90mm
1050 x 90 x 90mm
1050 x 90 x 90mm
1050 x 90 x 90mm
1050 x 90 x 90mm
1050 x 90 x 90mm
1050 x 90 x 90mm
1050 x 90 x 90mm
3