Jøtul F 470 SHD Series Installation And Operation Manual page 14

Jøtul f 470 shd series
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
ENGLISH
Fig. 19
6. When both side panels have been mounted, push them right
up to one another along the back edge and fasten at the top
only with a mount (Fig. 19 A).
7. Move the top plate into place and align carefully.
8. Finally, tighten all the screws.
9. If necessary, place the cover for the smoke outlet and inlet
air in the back edge.
10. Refit any parts that have been removed from the product.
4.5 Fitting a flue pipe with a top outlet
NB! With a top outlet, the flue pipe is installed after the outer
sides have been installed.
The product is supplied from the factory with the smoke outlet
fitted for the top outlet.
NB: It is important to remove the white foam plastic in the top!
1. Place the product in the correct position.
2. Place the top plate and the grate on top of the product.
3. Place the gasket on the edge of the flue pipe as illustrated
in Fig. 14 B.
4. Move the flue pipe into position.
NB: It is important for the joints/flue pipes to be sealed
completely. Air leaks may prevent them from operating properly.
14
4.6 Adjusting the burn chamber
height for the Jøtul F 470 SHD Series
Any unevenness between the burn chamber and the base/
pedestal/foot must be corrected.
This may also be done to reduce pressure on the draught valves
(prevents draught valves from becoming stiff).
Fig. 20
1. If the base has been mounted, the shelf and the inner plate
must be removed first.
2. Unscrew the screws (fig. 20 A) approx. 4 mm on both sides
of the product.
3. Unscrew B using an Allen key until you feel resistance in
the key. Then turn the adjustment screw to raise the burn
chamber as much as required.
4. Finally, tighten screws A.
5. Refit the base inner plate and shelf (only for base).