7. Remove the 4 screws
retaining the engine to
its pallet. Unpacking the
appliance
8. Taking great care not to
cut your hands on the
sheet metal edges, lift the
appliance out of its packing
base and place it in the
framing. Make
sure that the unit is at the right height with
consideration to the height of the hearth or
combustible fl ooring.
9. Remove the heat shield from the top of the appli-
ance case (3 screws). If using the top outlet, discard
the shield. If using a rear outlet, keep the shield to
reinstall after converting the top to rear outlet—see
next subsection.
Remove heat shield (3 screws)
Converting from Top to Rear Outlet (if
required)
This unit is supplied with a top vent outlet which can
be fi eld-converted to a rear vent outlet.
Please note that the rear outlet requires the
installation of the heat shield on top of the heater
case as indicated.
1. Remove the top outlet collar (3 screws).
Remove top outlet (3 screws)
Appliance Preparation
2. Swivel the collar and install as a rear outlet (3 screws).
Swivel the outlet so
that it is oriented
towards the rear and
reinstall to heater
(3 screws)
3. Reinstall the heat shield to the top of the appliance
case (3 screws).
Rear outlet with required heat shield
QUALIFIED
INSTALLER
Reinstall heat shield
to top of appliance
(3 screws)