10 Installation Instruction

10.1. Pipe length

• CORRECTION OF CAPACITIES
1. Correction of capacities according to the connecting pipe length.
The data of rated capacities (marked on the name plate) are based on 7.5 meters connecting pipe and horizontal installation.
2. For other pipe length of other installation multiply by the following correction factor to determine the revised cooling capacity.
Model No.
Cassette
R410A CS-F14DB4E5
type
CS-F18DB4E5
Note :
Piping elevation B = outdoor unit installed at top
Piping elevation C = outdoor unit installed at bottom
Piping Size / Length & Elevation
Piping size
Liquid /
Valve
Gas /
High
Low
6.35
3-ways
12.70
Piping
Piping
length
elevation
(A)
(B)
Valve
Max(m)
Max(m)
3-ways
30
30
35
Piping
Piping
elevation
Chargeless
(C)
Max(m)
Max(m)
20
20
Add
Refrigerant
(g/m)
20