Refrigerant Additional Charge; Position Of The Centre Gravity - Panasonic CS-F14DB4E5 Service Manual

Hide thumbs Also See for CS-F14DB4E5:
Table of Contents

Advertisement

10.2. Refrigerant additional charge

1. Piping installation by standard piping
• At the time of shipment from the factory, this unit is charged with enough refrigerant for an equivalent pipe length of 20 m.
(Refer the following table)
But when the piping length exceeds 20m, additional charge is required according to the following table.
Example:
CU-J14DBE5
In case of 30m long pipe (one way), the amount of refrigerant to be replenished is: (30 - 20) x 20 = 200g
Model Name
CU-J14DBE5
CU-J18DBE5

10.3. Position of the centre gravity

MODEL NAME
WIDTH (mm)
CU-J14DBE5
CU-J18DBE5
Liquid piping
(dia.mm)
6.35
6.35
OUTSIDE DIMENSIONS
DEPTH (mm)
900
320
900
320
Standard piping specification
Gas piping
Gas chargeless
(dia.mm)
length (m)
12.7
20
12.7
20
NET WEIGHT
HEIGHT (mm)
kg
795
69
795
69
36
Additional gas
volume (g/m)
20
20
CENTRE OF GRAVITY
X (mm)
Y (mm)
Z (mm)
560
150
560
150
320
320

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-j14dbe5Cu-j18dbe5Cs-f18db4e5

Table of Contents