Status LED's Operation Legend
TURBINE LED
BATTERY LED
GFI LED
Quick Start: DC Charge Controller for Honeywell Wind Turbine WT6500 - Rev 1.0 - 28Sep11
1.
NO LED
Turbine is sleeping or DC Charge Controller is off
2.
GREEN
Turbine is running
3.
RED
Turbine is stopped
4.
ONE RED BLINK
No Wind Speed – Turbine Voltage > 40VDC and Wind Speed = 0 MPH for
1 minute
5.
TWO RED BLINKS
Turbine over current – Turbine current > 9 Amps
6.
THREE RED BLINKS
No turbine fault – Turbine Voltage < 5VDC and Wind Speed > 10
MPH for 1 minute
7.
FOUR RED BLINKS
Turbine over voltage – Turbine Voltage > 170VDC
1.
GREEN
Batteries are charged (when battery voltage stays at 55V for a 48V
battery system).
2.
ONE RED BLINK
Low battery fault – Batteries are lower than 45V (for a 48V battery
system).
3.
TWO RED BLINKS
High battery fault – Batteries are higher than 58V (for a 48 Volts battery
system).
4.
THREE RED BLINKS
Charge over temp – Enclosure > 65°C or Heat Sink > 140°C
5.
FOUR RED BLINKS
Charge over current – Charge current > 24 Amps
1.
RED
Indicates GFI Fault