Care And Maintenance; Cleaning; Machine Oil Level - Pfaff 5483 Instruction Manual

Hide thumbs Also See for 5483:
Table of Contents

Advertisement

Care and maintenance

10
Care and maintenance
10

Cleaning

.01
10

Machine oil level

.02
Fig. 10 - 01
10 - 1
Clean the looper compartment .................. daily, several times if in continuous operation
Clean the entire machine .............................................................................. once a week
Machine oil level ...................................................................................... daily before use
Control/adjust air pressure ............................................................................... as required
Clean air filter of the lubricator/air-filter ............................................................ as required
These maintenance intervals are calculated for the average running time of a
single shift operation. If the machine is operated for a longer period, shorter
intervals are recommended.
Turn the machine off!
Danger of injury if the machine is started accidentally!
Tilt sewing head back.
Clean looper and looper compartment daily, several times if in continuous operation.
Using both hands, set the machine into an upright position!
Danger of crushing between the machine and table top!
1
Check oil level before each use.
The oil level must be between the
markings in the inspection glass.
If required refill oil through hole 1.
Only use oil with a mean
viscosity of 22.0 mm²/s at 40º C
and a density of 0.865 g/cm³ at
15º C!.
We recommend PFAFF
sewing machine oil. Order-No.
280-1-120 144.