Resetting The Reserve Attribute - HP StorageWorks XP24000 User Manual

Hitachi shadowimage for mainframe
Hide thumbs Also See for StorageWorks XP24000:
Table of Contents

Advertisement

6.
Click Apply in the Pair Operation window.
The settings are reflected in the storage system.
7.
Verify that the settings are reflected in the XP storage system.
You can check whether the attribute setting is updated or not on the Display Filter dialog box.

Resetting the Reserve Attribute

The Reset Reserve Attribute dialog box (see
attribute for (for example, unreserve) the volumes selected in the Pair Operation window.
Figure 30 Reset Reserve Attribute Dialog Box
The Reset Reserve Attribute dialog box displays the reserved volumes that you selected in the Pair
Operation window.
Volume: Information for the volume displays in XX:YY:ZZ (LDKC number: CU number: LDEV
number) format.
Emulation: The emulation type of the volume.
Capacity (Cyl): The number of the cylinders of the volume displays.
CLPR: The cache logical partition of the volume displays.
The OK button resets the reserve attribute of the SIz T-VOLs and sets the status of the volumes
back to simplex.
The settings will be displayed in the Preview List in the Pair Operation window. To apply the
settings to the storage system, click the Apply button in the Pair Operation window.
The Cancel button closes the Reset Reserve Attribute dialog box without resetting the reserve
attribute.
To unreserve one or more volumes (by resetting the reserve attribute):
1.
Make sure that the volumes you want to unreserve are no longer assigned to SIz pairs as
T-VOLs.
If the reserved volume is assigned to an SIz pair, delete the pair before you unreserve the
volume. See
2.
Go to the Pair Operation window, and select the CU image in the Tree.
3.
Select and right-click the desired Simplex volumes.
The menu displays.
To display only the Simplex volumes in the Volume List by using the Display Filter dialog box.
"Deleting Pairs" (page 84)
Figure 30 (page
67)) enables you to reset the reserve
for instructions on deleting SIz pairs.
Setting or Resetting the Reserve Attribute
67