Section E- Refrigeration System
Now make your
weld on the
suction line.
Make your weld
on the cap tube
first.

HEAT EXCHANGER REPLACEMENT

CAUTION
Always use the TORCH GUARD heat shield behind evaporator before attempting to
solder. The excessive heat from soldering will warp the plastic liner.
The original heat exchanger (Suction Line & Cap Tube Assembly) in this product is
enclosed in the insulation between the liner and the cabinet back. Because of this,
the original part cannot be removed. There is a service kit to bypass the internal
heat exchanger. It will be necessary to run a new heat exchanger down the back of
the product and bypass the internal heat exchanger.
Heat Exchanger Kit Contents:
1 Heat Exchanger
1 Drier-Filter
1 Armor Flex
2 Tape
15.
16.
17.
FIGURE 4
N OTE
If system is and/or old compressor oil is badly
contaminated, use the new 2 stage drier-filter, part #
5303918288. Refer to Service Bulletin Volume 23, # 3,
page 13.
Remove the
18.
heat shield
6 Screws
1 Cover
1 Package Permagum
1 Instruction Sheet
Push evaporator back in place and reinstall
plastic clamp at top. (See Figure 4.) There is
no need to replace the rivot.
Slide fan and bracket assembly in place and
connect defrost heater. Mount limit switch on
evaporator. Plug wiring harness into
connector on liner.
Replace Drier-Filter. Pump down and
recharge system.
Allow product to run and make sure
refrigerant is circulating. Reinstall evaporator
cover and machine compartment cover.