120
Section G - Ice & Water Dispenser
N OTE
Dispenser control board must be set for CUBE to operate the cube ice solenoid light
relay. Should read 0 voltage until the light switch button is pressed or an actuator is
pushed in, then reading should be 5 VDC + or - 10%.
AUGER MOTOR
±
5 VDC
10 %
WHEN ACTUATOR
IS ENERGIZED
Ice Actuator Switch
5.
Check voltage between the two terminals shown in figure 3 under WATER for
testing power from the control board to the relay that operates the water
valves. (Should read 0 voltage until the water actuator is pushed in, then you
should read 5 VDC ± 10%.)
6.
Check voltage between the two terminals shown in figure 3 under CUBE for
testing power from the control board to the relay that operates the cube ice
solenoid. (Should read 0 voltage until the ice actuator is pushed in, then you
should read 5 VDC ± 10%.)
7.
Check voltage between the two terminals shown in figure 3 under Auger for
testing power from the control board to the relay that operates the auger
motor. Should read 0 voltage until the ice actuator is pushed in, then you
should read 5 VDC ± 10%.
CUBE ICE SOLENOID
±
5 VDC
10 %
WHEN ACTUATOR
IS ENERGIZED
FIGURE 40
WATER VALVES
±
5 VDC
10 %
WHEN ACTUATOR
IS ENERGIZED
±
12 VDC
10 %
POWER SUPPLY TO
CONTROL BOARD
DISPENSER LIGHT
±
5 VDC
10 %
WHEN ACTUATOR
IS ENERGIZED
Water Actuator
Switch