Installation Example - Build-In With Horizontal Termination - Travis Industries GreenSmart 2 Fireplace 564 SS GSR2 Installation Manual

Built-in direct vent fireplace
Hide thumbs Also See for GreenSmart 2 Fireplace 564 SS GSR2:
Table of Contents

Advertisement

42

Installation Example - Build-In with Horizontal Termination

The framing, facing, and other building materials depicted below are for example only. Refer to local
building codes for framing, facing, and insulating requirements in your area.
Side View
See "Vent Termination"
NOTE FOR 2 x 4 (51mm X 102mm) EXTERIOR
WALLS:
When installed with a 2x4 (51mm X 102mm)
exterior wall, the termination may not fit flush against
the exterior wall. You may wish to place framing
around the termination to fill the gap.
Top View
NOTE:
1/2'' (13mm) Clearance to
sides and back of fireplace.
© Travis Industries
Installation
for full requirements.
Horizontal Termination*
4'' (102mm) Section*
(make sure all vent clearances are met)
(for qualified installers only)
SIDE OF FIREPLACE
Firestop
Insulation
NOTE: If required to use drywall inside
the firebox enclosure, make sure to alter
the framing accordingly.
Drywall
Optional Tile
4140221
Drywall
Optional Tile
100-01345

Advertisement

Table of Contents
loading

This manual is also suitable for:

564 ss greensmart 2

Table of Contents