Installation Example - Build-Out (Dog-House) with Hor. Termination

The framing, facing, and other building materials depicted below are for example only. Refer to local
building codes for framing, facing, and insulating requirements in your area.

Side View

NOTE FOR 2 x 4 (51mm X 102mm) EXTERIOR
WALLS:
When installed with a 2x4 (51mm X 102mm) exterior
wall, the termination may not fit flush against the exterior
wall. You may wish to place framing around the
termination to fill the gap.
Top View
NOTE:
1/2'' (13mm) Clearance to
sides and back of fireplace.
© Travis Industries
Installation
See "Vent Termination"
for full requirements.
Horizontal Termination*
4'' (102mm) Section*
Firestop
(make sure all vent clearances are met)
(for qualified installers only)
SIDE OF FIREPLACE
Insulation
Vapor
Barrier
Drywall
Optional Tile
4140221
Drywall
Optional Tile
NOTE:
In colder climates the fireplace may
require an insulated enclosure.
NOTE: If required to use drywall inside
the firebox enclosure, make sure to alter
the framing accordingly.