Health & Safety Precautions Specification Chimney Hearth & Fire Surround Central Heating System System Controls Connection to Flues Soot Doors Unpacking The Stove Fitting The Stove To Its Stand Pre Lighting Check Commissioning Dimensions Parts Lists Certification Ref. Cove 2B 05.10...
Housecoal doubles, trebles or cobbles may all be burnt. Do not use singles, small nuts, or coal dust Your Charnwood stove is fitted with a multifuel grate which enables both solid fuels and wood to be burned equally effectively. The grate...
OPERATING INSTRUCTIONS ® should be kept well ventilated. has two positions:- At first only light a small fire and burn it slowly for two hours to allow 1) In the solid fuel position the grate bars are vertical with gaps in any residual moisture in the bricks to evaporate.
To revive the fire, add some small logs and open the thermostat To make ash removal easier there is a special Charnwood ash carrier control to maximum. When the fire is burning well load on more fuel available.
Manufacturer or their approved agents. the installer will have provided alternative means, such as a soot door. Use only genuine Charnwood replacement parts. After sweeping the chimney the appliance flue outlet and the flue...
Page 8
OPERATING INSTRUCTIONS ® Door Glass Blacks Up b) Let the fire out and safely dispose of the fuel from the appliance. Keeping the glass clean requires a certain amount of c) Check for flue or chimney blockage, and clean if required.
Expert advice should be sought if necessary. IF YOU NEED FURTHER HELP If you need further help with your Charnwood Cove then your Installer will be able to provide the answers to most questions. Your Local Charnwood Premier Dealer has a great deal of experience and will also be able to provide helpful advice.
INSTALLATION INSTRUCTIONS ® HEALTH & SAFET Y PRECAUTIONS CHIMNEY Please take care when installing the stove that the requirements of In order for the appliance to perform satisfactorily the chimney height the Health and Safety at Work Act 1974 are met.
INSTALLATION INSTRUCTIONS ® Fig. 6. Typical Central Heating & Hot Water System If in doubt as to the positioning of the stove expert advice should be Using 4 Boiler Tappings sought either from the supplier or the local building inspector.
It will also ensure that priority is given to the domestic hot water. These thermostats are available from Charnwood if you are unable to obtain them locally. CONNECTIONS TO FLUES There are several ways of connecting the stove to the flue. These are illustrated in figures9 to 12 Fig.
INSTALLATION INSTRUCTIONS ® Fig. 13 The pallet is intended to be cut up and used for kindling fuel. FITTING THE STOVE TO ITS STAND 1. Centre stand The Stand is first positioned on the hearth in the desired position of the stove.
Page 14
INSTALLATION INSTRUCTIONS ® of time for the fire cement and mortar to dry out, the stove should be lit and checked to ensure that smoke and fumes are taken from the appliance up the chimney and emitted safely. Also check all joints and seals.
# Please specify colour when ordering.” contact the manufacturer at the address shown. This drawing is for identification purposes only. charnwood BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T:+4 4 (0)1983 537799 • F:+4 4 (0)1983 537788 • SPARES@CHARNWOOD.COM • WWW.CHARNWOOD.COM ®...
ch ar nw o od A . J W E L L S & S O N S L T D Bishops Way, Newpor t, Isle of Wight PO30 5WS, United Kingdom A Division of A .J.Wells & Sons Limited Registered in England No. 03809371 EN13240:2001 Roomheater &...
Page 18
BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T:+44 (0)1983 537777 • F:+44 (0)1983 537788 • CHARNWOOD@AJWELLS.CO.UK • WWW.CHARNWOOD.COM ® A D i v i s i o n o f A . J . W e l l s & S o n s L i m i t e d R e g i s t e r e d i n E n g l a n d N o . 0 3 8 0 9 3 7 1...