Charnwood C-SERIES Operating & Installation Instructions Manual

Charnwood C-SERIES Operating & Installation Instructions Manual

C series wood stove

Advertisement

®
charnwood
C-SERIES
Operating & Installation Instructions

Advertisement

Table of Contents
loading

Summary of Contents for Charnwood C-SERIES

  • Page 1 ® charnwood C-SERIES Operating & Installation Instructions...
  • Page 3: Table Of Contents

    C-SEVEN Parts Lists ....22 C-EIGHT Parts Lists ....23 Ref. C-Series v2 01.14...
  • Page 4: Operating Instructions

    Congratulations on becoming the owner of a HETAS approved These appliances have been approved by HETAS as intermittent Charnwood C-Series Stove. Your stove has been approved by DEFRA operating appliances for burning dry seasoned wood logs only. to burn wood logs in a smoke control area if it is used in accordance HETAS approval does not cover the use of other fuels either alone or with these instructions.
  • Page 5: Lighting

    Charnwood. few small dry logs. Open the air control fully (see Fig. 2). Light the REFUELLING paper or fire lighters.
  • Page 6: Reduced Burning

    OPERATING INSTRUCTIONS ® Fig.3. Throat Plate Position and Lowering To make ash removal easier there is a special Charnwood ash carrier available. This may be purchased from your supplier or, in case of Throat Plate difficulty, from Charnwood. REDUCED BURNING For reduced burning the fire door must be closed.
  • Page 7: Trouble Shooting

    OPERATING INSTRUCTIONS ® deposits with the consequent risk of flue blockage. It is therefore therefore, when lighting the stove allow the firebed to become well recommended that the chimney be swept a second time within a established before closing the air control. This may also be necessary month of regular use after installation.
  • Page 8: Co Alarm

    “Warning Note” above. IF YOU NEED FURTHER HELP If you need further help with your Charnwood then your Installer will be able to provide the answers to most questions. Your Local Charnwood Premier Dealer has a great deal of experience and will also be able to provide helpful advice.
  • Page 9: Installation Instructions

    INSTALLATION INSTRUCTIONS ® to give advice, if necessary. considered a substitute for either installing the appliance correctly or HEALTH AND SAFET Y PRECAUTIONS Specification C-Four C-Five C-Six C-Seven C-Eight Please take care when installing the stove that the requirements of Nominal Heat the Health and Safety at Work Act 1974 are met.
  • Page 10: Hearth & Fire Surround

    INSTALLATION INSTRUCTIONS ® Fig. 4. Vertical Register Plate With Bricked Up Fireplace If you find that the chimney is in poor condition then expert advice should be sought regarding the necessity of having the chimney lined. Soot Door If it is found necessary to line the chimney then a lining suitable for In Side or Rear Of Chimney Solid Fuel must be used.
  • Page 11: Connection To Flues

    Stove Model C-Six, C-Seven & C-Eight..150mm (6") i/d pipe. This may be stainless steel, cast iron, or thick wall steel pipe. Straight lengths of Charnwood Pipe to match the stove are available if required. For top outlet installations on the C Five, Six & Seven the flue collar There are several ways of connecting the stove to the flue.
  • Page 12: Unpacking The Stove

    Charnwood C-FIVE, Charnwood C-SIX, bolts. These 4 bolts are required for levelling or fixing on the Store Charnwood C-SEVEN and Charnwood C-EIGHT have been Stand. The Stove may now be moved to its final position. The pallet recommended as suitable for use in smoke control areas when is intended to be cut up and used for kindling fuel.
  • Page 13: Certification

    A.J WELLS & SONS LTD A.J WELLS & SONS LTD Bishops Way, Newport, Isle of Wight PO30 5WS, United Kingdom A Division of A.J.Wells & Sons Limited Registered in England No. 03809371 CE Certificate for compliance with EN13240:2001 and UK HETAS requirements. EN13240:2001 C SERIES ROOMHEATERS FIRED BY SOLID FUEL...
  • Page 14: C-Four Dimensions

    C-FOUR DIMENSIONS (mm) ® Plan View 140 i/d to suit 125mm (5") flue pipe Optional Vertical Rear Flue Adapter 64 OD 61 ID Front Side Rear...
  • Page 15: C-Five Dimensions

    C-FIVE DIMENSIONS (mm) ® 140 i/d to suit 125mm (5") Optional Vertical Rear Flue Adapter Plan View flue pipe Front Side Rear...
  • Page 16: C-Six Dimensions

    C-SIX DIMENSIONS (mm) ® Plan View 156 i/d to suit 150mm (6") Optional Vertical Rear Flue Adapter flue pipe To suit 80mm ducting Front Side Rear...
  • Page 17: C-Seven Dimensions

    C-SEVEN DIMENSIONS (mm) ® Optional Vertical Rear Flue Adapter 156 i/d to suit 150mm (6") flue pipe 79 OD Front Side Rear...
  • Page 18: C-Eight Dimensions

    C-EIGHT DIMENSIONS (mm) ® Optional Vertical Rear Flue Adapter 156 i/d to suit 150mm (6") flue pipe 163.0 Front Side Rear...
  • Page 19: C-Four Parts Lists

    Description. In case of difficulty contact the manufacturer at the address shown. This drawing is for identification purposes only. charnwood BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T:+4 4 (0)1983 537799 • F:+4 4 (0)1983 537788 • SPARES@CHARNWOOD.COM • WWW.CHARNWOOD.COM ®...
  • Page 20: C-Five Parts Lists

    This drawing is for identification purposes only. Description. In case of difficulty contact the manufacturer at the address shown. charnwood BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T:+4 4 (0)1983 537799 • F:+4 4 (0)1983 537788 • SPARES@CHARNWOOD.COM • WWW.CHARNWOOD.COM ®...
  • Page 21: C-Six Parts Lists

    Description. In case of difficulty contact the manufacturer at the address shown. This drawing is for identification purposes only. charnwood BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T:+4 4 (0)1983 537799 • F:+4 4 (0)1983 537788 • SPARES@CHARNWOOD.COM • WWW.CHARNWOOD.COM ®...
  • Page 22: C-Seven Parts Lists

    Description. In case of difficulty contact the manufacturer at the address shown. This drawing is for identification purposes only. charnwood BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T:+4 4 (0)1983 537799 • F:+4 4 (0)1983 537788 • SPARES@CHARNWOOD.COM • WWW.CHARNWOOD.COM ®...
  • Page 23: C-Eight Parts Lists

    Description. In case of difficulty contact the manufacturer at the address shown. This drawing is for identification purposes only. charnwood BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T:+4 4 (0)1983 537799 • F:+4 4 (0)1983 537788 • SPARES@CHARNWOOD.COM • WWW.CHARNWOOD.COM ®...
  • Page 24 BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T : + 4 4 ( 0 ) 1 9 8 3 5 3 7 7 7 7 • F : + 4 4 ( 0 ) 1 9 8 3 5 3 7 7 8 8 • C O N T A C T U S A T W W W . C H A R N W O O D . C O M ®...

This manual is also suitable for:

C4C6C5C8C7

Table of Contents