Page 1
® skye E700 E700 c h ar n wo o d c h ar n wo o d Operating & Installation Instructions...
Page 2
2025 JAN. FEB. MAR. APR. JUNE JULY AUG. SEPT. OCT. NOV. DEC. MANUFACTURED BY: / FABRIQUÉ PAR: Charnwood, Bishops Way, Newport PO30 5WS, United Kingdom / Royaume Uni JANV. FEV. MARS. AVR. JUIN JUILLET AOUT. SEPT. OCT. NOV. DEC. TESTED TO: / TESTÉ À: U.S.
C H A R N W O O D C O N T R O L A P P C H A R N W O O D C O N T R O L A P P SKYE E700 DIMENSIONS CERTIFIC ATION F22-758 Ref. skye E700 03.10.22 REV H...
Avoid damaging the temperature sensor, located on the right hand side, above upper baffle. SERVICING Stove should be serviced by a professional at least once a year. LIGHTING AND CONTROLLING THE FIRE Suitable fuels for your Charnwood: Wood logs Unsuitable fuels: Petroleum coke Liquid fuel Household waste Place 2-3 12”...
Log moisture content of less than 20% is recommended. Your Charnwood Skye is fitted with a multi grate to enable wood to PETROLEUM COKE IS NOT SUITABLE FOR USE ON...
OPERATING INSTRUCTIONS ® 1) In the wood position the grate bars are horizontal, allowing the any residual moisture in the chimney to evaporate. combustion air to come round the sides of the grate and over the top In Automatic or Room Temperature modes, the stove will ensure of it.
(1 – 5). enables the graphing data to be viewed on the device and also the ability to update the stove firmware if Charnwood issue new Room Temp Mode – User defines a a set room temperature (61 –...
To make ash disposal easier there is a special ash container available Logs should be evenly distributed and are best placed from side to - the Charnwood ash carrier. This may be purchased from your side, but not touching either side of the firebox or the glass in the supplier or, in case of difficulty, from Charnwood.
OPERATING INSTRUCTIONS ® wiping over with a dry cloth. Any stubborn deposits on the glass may USE ONLY GENUINE CHARNWOOD REPLACEMENT be removed with a proprietary stove glass cleaner or ceramic hob PARTS, DO NOT USE SUBSTITUTE MATERIALS. cleaner. Do not use abrasive cleaners or pads as these can scratch CREOSOTE FORMATION AND NEED FOR the surface which will weaken the glass and cause premature failure.
OPERATING INSTRUCTIONS ® and back brick, then, making sure the two halves are fitted closely TROUBLE SHOOTING together, slide the joining clip back onto the front edge, making sure Fire Will Not Burn that it is central on the join.The upper throat plate is positioned on Check that: top of the air wash tubes and is located with studs into the two holes on the bracket attached to the air wash manifold.
Persistent fume emission is potentially dangerous and must not be tolerated. If fume emission does persist, then the following If you need further help with your Charnwood then your Installer immediate actions should be taken: will be able to provide the answers to most questions. Your Local...
INSTALLATION INSTRUCTIONS ® UNPACKING THE STOVE External air supply kits are available please contact Charnwood for more information. The stove arrives bolted and strapped to its pallet. There must be This stove is capable of intermittent operation, and is not suitable for adequate facilities for unloading and manoeuvring into position.
(12 Pa). If in doubt about the chimney seek expert advice. the chimney connector and 2” (51 mm) to either side. For the 6” (150 mm) connector used with the Skye E700, the protector must be a minimum of 10” (254 mm) wide, central under the connector.
Page 15
Part No. Listed Chimney 005/AU081 fitted to the rear of the stove. A spacer is also required to attach the optional vertical rear flue connector to the Skye E700 Part no. 010/AU021. Fig. 11. Clearances from wooden fire surrounds...
If the vertical rear flue connector or the top flue connection is used, then the chimney may be swept through the appliance. A spacer is required to attach the optional vertical rear flue connector to the Skye E700. The stove comes with the blanking plate fitted to the top flue outlet.
PRE LIGHTING CHECK Alternative Soot Door Positions Masonry Ensure that upper throat plate (Skye E700, top flue outlet Chimney connection only) and the throat plate is fitted in the roof of the Metal Closure Plate appliance. The location and positioning of the throat plate is shown With Soot Door Vert.
Optional rear heatshield resource is used to responsibly recycle the electronic components of the Skye E700 when they reach the end of their life. A description Fig. 20. Chimney Connector. of how to remove all the electrical components from the body of the stove, can be found below.
Page 19
INSTALLATION INSTRUCTIONS ® of how to remove all the electrical components from the body of the stove, can be found below. Electronic Component Removal The air control assembly containing most of the electronics is easily removed, by removing the cable tray, unplugging the seven cables from the front, then loosening the bolts on either side of the assembly, before sliding it forwards and lowering it away from the stove.
SKYE E700 DIMENSIONS ® Optional rear flue adaptor To suit 150mm (6”) flue pipe PLAN FRONT SIDE REAR...
Page 21
PARTS LIST Charnwood Skye E700 Store Stand Parts List ® Issue B Item Part No. Description Item Part No. Description 008/AU035S Rope Door Seal Inc Adhesive 010/CU063 Door Latch 008/FW29 Door Seal Adhesive 010/CU064 Door Latch Bracket 006/AU018 Glass 38# 010/CU060...
Page 22
PARTS LIST Charnwood Skye E700 Low Parts List ® Issue B Item Part No. Description Item Part No. Description 008/AU035S Rope Door Seal Inc Adhesive 002/BU042 Lower Hinge 008/FW29 Door Seal Adhesive 010/CU063 Door Latch 006/AU018 Glass 010/CU064 Door Latch Bracket...
Page 23
PARTS LIST Charnwood Skye 7 E700 Air Box Assembly Parts List ® Issue A Item Part No. Description 008/CU110 Air Control Gasket 008/CU235 Circuit Board Mount 008/CU242 Airbox Cover Gasket 008/EL325 Ribbon Cable Connector 010/CU231 Lower Plate Assembly 010/CU040 Airbox Cover...
Bishops Way, Newport, Isle Of Wight PO30 5WS, United Kingdom A Division of A.J.Wells & Sons Limited Registered In England No. 03809371 EN13 UL 1482-2020 ULC S627:20210:2001 ROOMHEATERS FIRED BY SOLID FUEL Skye E700 MODEL: EC CERTIFICATE OF CU44-CPD-2020 CONFORMITY NO: FUEL TYPE:...