Update Firmware; Reset Calibration Values - Ioline FlexJet User Manual

Hide thumbs Also See for FlexJet:
Table of Contents

Advertisement

Update Firmware

1.
Press the CAPS LOCK key on the keyboard so that the CAPS
LOCK light is lit.
2.
With TeraTerm
open, turn FlexJet power off then back on. A
message should appear in the TeraTerm
3.
Within 8 seconds of turning on power, press the Y key on the
keypad. This prepares the FlexJet to accept new software. The
carriage should NOT move after pressing the Y key.
4.
In TeraTerm, choose File>Send File.
5.
Use the window to browse to c:\Ioline\Firmware and double
click on the firmware file (usually xxxxx.mot, where xxxxx is
the version number). A window will appear that shows the
transfer progress.
6.
When the transfer window closes, press the Z key. The FlexJet
will finish updating the firmware for approximately 2 minutes.
A few messages will appear indicating progress.
7.
When the download process is complete, the carriage will go
through the Power On sequence and park the Service Station.
TeraTerm
will show that the new software is installed by
displaying the version number. The keypad OK light turns red
and the Square light turns green.
8.
The FlexJet is ready for normal use. Perform test plots and
verify that the calibration values are correct. If anything is not
performing correctly, reset calibration values as described un-
der the Reset Calibration Values section in this chapter.

Reset Calibration Values

Perform the steps below if calibration values have been altered:
1.
With the FlexJet in STOP mode, use the arrow keys to move
the carriage to the center of the traverse.
2.
Turn power off on the FlexJet.
3.
Copy the factory calibration values from the white sticker
inside the service station (see Figure 34.) If no sticker is present,
recalibrate the machine using the procedure available in the
FlexJet User Guide.
4.
Press and hold the Unroll key on the keypad then turn FlexJet
power on.
5.
When the OK light turns red, release the key.
6.
Use the FlexJet Control Center software to re-enter the calibra-
tion values copied from the sticker OR perform the calibration
using the directions in this chapter.
7.
Turn power off then back on to ensure the new calibration val-
ues take affect. Perform test plots to verify proper calibration
and operation.
8.
If you have any difficulties, please contact Ioline Customer
Service.
window.