Step No.
Setting Method
Step 16
Press the EQUALIZER button.
Step 17
Press the EQUALIZER button.
Step 18
Press the EQUALIZER button.
Step 19
Press the EQUALIZER button.
•
: Setting value
G) ADJUST setting
Setting Method
Step No.
Step 1
Test mode STOP state
Step 2
Press the EQUALIZER button eight times. [ E E P R O M_ S E T ]
Step 3
Press the TAPE REC button.
Step 4
Press the EQUALIZER button six times.
Step 5
Press the TAPE REC button.
Step 6
Press the EQUALIZER button.
Step 7
Press the EQUALIZER button.
Step 8
Press the EQUALIZER button.
Step 9
Press the EQUALIZER button.
Step 10
Press the EQUALIZER button.
Step 11
Press the EQUALIZER button.
Step 12
Press the EQUALIZER button.
•
: Setting value
6. TEST-PLAY mode
(For confirmation of the playback ability at the named address.)
Setting Method
Step No.
Step 1
Test mode STOP state
Step 2
Press the X-BASS button.
Step 3
Press once the DISP/CHARACTER button. ADDRESS setting (Target address initial value is indicated)
Press once the TAPE REC button.
Step 4
Continuous playback (pit section) (Address + C1 error indication)
Continuous playback (groove section) (Address + C1 error indication)
Step 5
Press once the DISP/CHARACTER button. (Address + ADIP error indication)
Continuous playback (groove section) (HIGH reflection STEP 6)
Step 6
Continuous playback (pit section) Address + Jitter
Continuous playback (groove section)
Step 7
Press once the MD STOP button.
• Whenever the X-BASS button is pressed in the address setting mode, the address changes as follows.
0 0 3 2 → 0 3 C 0 → 0 7 0 0 → 0 8 A 0 → 0 9 5 0 → 0 0 3 2 → ............
7. TEST-REC mode
With recording mini disk (For confirmation of the playback ability at the named address.)
Step No.
Setting Method
Step 1
Test mode STOP state
Step 2
Press twice the X-BASS button.
Step 3
Press once the DISP/CHARACTER button. ADDERS setting (indication of address initial value)
Step 4
Press once the TAPE REC button. Continuous recording
Step 5
Press once the MD STOP button. TEST-REC menu
• Whenever the X-BASS button is pressed in the address setting mode, the address changes as follows.
0 0 3 2 → 0 3 C 0 → 0 7 0 0 → 0 8 A 0 → 0 9 5 0 → 0 0 3 2 → ............
8. INNER mode
Step No.
Setting Method
Step 1
Test mode STOP state
Step 2
Press the MD PLAY button.
Step 3
Press once the TAPE REC button. INNER switch position measurement
Step 4
Press once the MD STOP button.
•
: Address
Display
[G A L S G _ _ _
]
[H A L S O F S _
]
[L A L S O F S _
]
[G A L S O F S _
]
Display
[ t s m
e
]
[ _ _ F o c u s _ _ _ ]
[A D J S E T _ _ _ _ ]
[C O K _ _ _ _ _
]
[F A T _ _ _ _ _
]
[T A T _ _ _ _ _
]
[C A T _ _ _ _ _
]
[F A B _ _ _ _ _
]
[S T R _ _ _ _ _
]
[S F S _ _ _ _ _
]
[S T C _ _ _ _ _
]
Remarks
The AUTO preliminary adjustment should have been completed.
TEST-PLAY menu
TEST-PLAY menu
Remarks
The AUTO preliminary adjustment should have been completed.
TEST-REC menu
Remarks
INNER menu
(SUBQ address and C1 error are also indicated.)
INNER menu
– 41 –
CD-MD3000H/CD-MD3000W
Display
[ t s m
[ T E S T _ P L A Y _ ]
[ A D R E S _ 0 0 3 2 ]
[s
[a
[a
[s
[a
[ T E S T _ P L A Y _ ]
Display
[ t s m
[ T E S T _ R E C _ _ ]
[ a 0 0 3 2 _ p w
[ a
[ T E S T _ R E C _ _ ]
Display
[ t s m
[ _ _ I N N E R _ _ ]
[s
[ _ _ I N N E R _ _ ]
e
]
c
]
c
]
a
]
j
]
j
]
e
]
]
_ p w
]
e
]
c
]