Spx-5 Tiller System Alarm Messages - Raymarine SmartPilot X-5 Operating Manual

Tiller & gp tiller
Hide thumbs Also See for SmartPilot X-5:
Table of Contents

Advertisement

26
Symptom
The SPX-5 Tiller system will
not auto advance to the next
waypoint
Jog (+ and -) buttons do not
work in standby mode.

SPX-5 Tiller system alarm messages

If a fault or failure occurs in the SPX-5 Tiller system, an appropriate alarm message is
generated.
If this happens and unless otherwise stated, press standby to clear the alarm and
return to manual control, before you attempt to resolve the problem. If more than one
alarm occurs, as each alarm is cleared, the next is displayed.
Alarm messages, possible causes and remedies are detailed in the following table.
Alarm message
CURRENT LIMIT
DRIVE STOPPED
LOW BATTERY
LRN FAIL 1, 2, 4, 5
or 6
MOT POW
SWAPPED
NO DATA
SmartPilot X-5 Tiller & GP Tiller Operating Guide
Possible cause and remedy
No bearing to waypoint information received from the
navigator.
Vessel type is set incorrectly. Check vessel type is set to
SAILBOAT (see SmartPilot X-5 Tiller & GP Tiller Installa-
tion & Setup Guide) .
Possible cause and remedy
Serious drive failure – the drive is taking too much current due to short-
circuit or jamming. Check the drive unit.
The SPX-5 Tiller system is unable to turn the rudder. This can occur if
the weather load on helm is too high, or if the (optional) rudder position
sensor has passed beyond the preset rudder limits or rudder end-stops.
Check drive and, if appropriate, the rudder position sensor
Supply voltage has dropped below acceptable limits.
• press standby to clear the alarm and return to hand steering
• start the engine to recharge the battery
AutoLearn not completed successfully.
Failure codes:
1 = AutoLearn has not been carried out (default setting)
2 = AutoLearn failed, usually due to manual interruption
4 = AutoLearn failed, probably due to drive or compass failure
5 = AutoLearn failed, probably due to motor current limiting
6 = AutoLearn failed, probably due to boat spinning
Repeat the AutoLearn procedure (see SmartPilot X-5 Tiller & GP Tiller
Installation & Setup Guide) .
Motor cables are connected to power terminals (and power cables are
connected to motor terminals) at course computer. Turn off power and
swap over connections.
Caused by any of the following situations:
• the compass is not connected
• the SPX-5 Tiller system is in Wind Vane mode but has not received
wind angle data for 30 seconds
• the SPX-5 Tiller system is in Track mode and:
• is not receiving SeaTalk navigation data, or
• the position sensor (GPS) is receiving a low strength signal – this will
clear when the signal improves
Check connections to the compass, wind instrument and navigator.
Note: The SPX-5 Tiller system stops adjusting the heading as soon as it
loses data.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents