NOTE:
• All control inputs are dry-contact, normally open, inputs. DO NOT apply external voltage sources to these inputs.
• All inputs are connected with respect to COMMON terminal.
• The status light will blink once when its corresponding input is activated.
1
COM: Circuit common (reference for all logic input)
• Two (2) terminals to provide extra common connection point.
2
CYCLE: (Typically for use with doorbell button or hardwired keypad)
• Each activation at this input will cycle the operation as follows:
....→ OPEN → STOP → CLOSE → STOP → OPEN → ...
3
SAFETY: (Typically for use with photo beam device, loop detector
or other non-contact sensors)
• Activation of this input while the gate is closing will cause the gate to
stop and return to the opened position.
• Activation of this input while the gate is opening has no effect (gate
will continue to open).
• Activation of this input while gate is idle will prevent gate from closing.
4
EXIT: (Typically for use with exit loop or wand)
• Activation of this input will open the gate if it's not already at the
open position.
• Activation of this input while at open limit will restart the auto close time
(if enabled).
5
SHADOW: (Typically for use with loop detector device)
• This input is only monitored when the gate is at the fully open
position. At any other position, activation of this input has no effect on
gate operation.
• Activation of this input while gate at the fully open position will
prevent gate from closing.
6
CLOSE EDGE: (Typically for use with safety edge device)
• Activation of this input while the gate is closing will cause the gate to
stop and reverse direction for approximately 2 seconds.
• Activation of this input while the gate is opening has no effect (gate will continue to open).
• Activation of this input while gate is idle will prevent gate from closing.
7
OPEN EDGE: (Typically for use with safety edge device)
• Activation of this input while the gate is opening will cause the gate to
stop and reverse direction for approximately 2 seconds.
• Activation of this input while the gate is closing has no effect (gate
will continue to close).
• Activation of this input while gate is idle will prevent gate from opening.

Input Connections

30
ORG
RED
BLK
GRN
WHT
BLU
BRN
ORG
RED
BLK
1
COM
COM
2
CYCLE
3
SAFETY
4
EXIT
5
SHADOW
CLOSE
6
EDGE
OPEN
7
EDGE
GRN
BLK
RED