Example - CipherLab 1166 User Manual

Hide thumbs Also See for 1166:
Table of Contents

Advertisement

1166/1266 Barcode Scanner

EXAMPLE

You may run HyperTerminal.exe on the host computer to send serial commands to the
1166/1266 scanner via RS-232 or BT SPP.
For the scanner to turn off the beeper and save the setting –
#@0319<CR>
#@9999<CR>
For the scanner to change the beeper frequency to 8 kHz (for Good Read Beep only)
and beep –
#@0046<CR>
#@////<CR>
For the scanner to change to Auto Power Off mode and save the setting –
#@0068<CR>
#@9999<CR>
Note: (1) For RS-232, you can only configure the first scanner that connects to 3666. To
identify the scanner, you may send the serial command to have it respond with a
beep.
(2) For BT SPP, you can configure up to seven scanners at the same time.