Cardioid microphones/wide cardioid microphones

Advertisement

Preamplifier frequency range:
4012 and 4016: 20 Hz to 50 kHz ±0.2 dB, 5 Hz to 150 kHz -3 dB
4011-TL and 4015-TL: 20 Hz to 40 kHz -3 dB (loaded with 2x10 kOhm//
10 nF - equivalent to 100 m cable)
Preamplifier output impedance:
<200 Ohm
Cable drive capability:
4011-TL and 4015-TL: Up to 100 m (328 ft)
4012 and 4016: With HMA5000: Up to 300 m (984 ft)
4012 and 4016: With PCC4000: Up to 100 m (328 ft)
Polarity:
4011-TL and 4015-TL: Positively increasing sound pressure
produces positive-going voltage at pin 2. Pin 1: Ground, Pin 2:
Signal +, Pin 3: Signal. (See Fig. 5)
4012 and 4016: Positively increasing sound pressure produces
positive-going voltage at pin 4. Pin 1: Ground, Pin 2: Not used,
Pin 3: 130 V DC preamplifier supply, Pin 4: Signal. (See Fig. 7)
Difference frequency distortion:
(DF2, DF3, Df = 70 Hz) <0.5 % at 110 dB SPL peak
Influence of vibration:
<71 dB equivalent SPL for 1 m/s
sensitivity
Influence of magnetic field:
45 dB equivalent SPL for 80 A/m, 50 Hz in direction of greatest
sensitivity
Operating temperature range:
-10 to +55°C (+14 to 131°F)
Dimensions:
Microphone length: 175 mm (6.89 in)
Microphone diameter: 19 mm (0.75 in)
Capsule diameter: 19 mm (0.75 in)
Weight:
165 g (5.82 oz)
Connector:
4011-TL and 4015-TL: 3-pin XLR-M (Standard P48)
4012 and 4016: 4-pin modified XLR-M (high-voltage)
in direction of greatest