Generator Diagnosis And Testing; Generator Output Test; Generator Voltage Test - Ford LRG-423 Service Manual

2.3 litre industrial engine
Table of Contents

Advertisement

03-72
Auxiliary Systems
03-72
GENERATOR
DIAGNOSIS
ANDTESTING
NOTE: The generator
(main) wiring diagram
(14305)
for the engine,
is found later in this section.
Before performing
generator
tests on the unit, note
conditions
such as: slow cranking,
dead battery,
charge indicator
lamp stays on with engine
running,
etc. This information
will aid in isolating
the part of the
,
system causing
the symptom.
J5695-A
Item
Part
Number
Description
1
-
Mounting Screws (Ground
Connection)
(4 req' d) Tighten to
1.7-2.8 Nom (15-25 In-Lb) (Part
of 10316)
2
-
Brush Holder Screw (Test Point
" F" ) (Part of 10316)
3
-
Brush Holder Screw (Test Point
" A" ) (Part of 10316)
4
-
I Circuit 904 (Part of 14305)
5
-
S Circuit 4 (Part of 14305)
6
-
A Circuit 36 (Part of 14305)
7
10328
Rotor Slip Ring
Visuall inspection
Preliminary
checks to the charging
system should be
made regardless
of the fault condition.
These checks
include:
1.
Check battery
posts and cable terminals
for clean
and tight connections.
Clean the posts and the
cables to ensure
good electrical
contact.
2.
Check for secure connections
at the generator
output, regulator,
and engine ground. Also check
the connection
at the load distribution
point
(starter relay).
3.
Check the fuses/fuse
links and wiring to the
generator
to ensure that they are not burned
or
damaged.
This condition,
resulting
in an open
circuit or high resistance,
can cause erratic or
intermittent
charging
system
concerns.
4.
Check the battery voltage.
If the voltage
is less
than 12.3 volts with the engine and all
accessories
off, charge battery
before
proceeding.
In order to check the generator,
the use of Rotunda
Starting
and Charging
System Tester 078-00005
(VAT-40) or equivalent,
is recommended.
Generator Output Test
NOTE: Refer to the test equipment
user' s manual
for
complete
directions
on examining
the charging
system.
1.
Switch the tester to ammeter
function.
2.
Connect
the positive
and negative
leads of the
tester to the battery.
3.
Connect
current probe to generator
B+ output
lead Circuit 38 (BWO (to measure
generator
output).
4.
With the engine
running at 2000 rpm, adjust the
VAT-40 or equivalent
load bank to determine
the
output of the generator.
Generator
output should
be greater
than values
given in graph below. If
not, refer to symptom
chart in this section
for
diagnostic
procedure.
Generator Voltage Test
1.
Switch the tester to the voltmeter
function.
2.
Connect
the positive
lead to the generator
A-terminal
connector
and the negative
lead to
ground.
AMPS
95 AMP GENERATMI
loo0
1500
ENGINE SPEED
3.
Turn off all electrical
accessories.
NOTE: During this check, the voltage
may be between
13.0-15.5
volts. If voltages
are out of range, refer to
symptom
chart in this section for diagnostic
procedure.
4.
With the engine
running at 2000 rpm, check the
generator
voltage.