The information is included in a list that can
contain up to 50 elements, over that limit the
information is stored starting by position 1
(previous information will be lost).
The following menu displays the LOG:
MAINTENANCE
Notes:
All errors or faults are stored, except when blocks
occur (coffee, instant product, beverage, water).
Ways of accessing stored information:
OPERATION
Accessing log
Resetting log
Viewing
all
the
information (including
cancelled information)
50
For more information visit www.Gumball.com | 800-260-0010 | +1-214-550-5079
ERROR LOG
ERROR LOG
ERROR LOG RESET
BOILER EMPTYING
METHOD
Using the Maintenance/
LOG MONITOR menu
Use the appropriate
menu
Enter the error list and
press the beverage
button 5
/03
ERROR LOG
Mxx Eyy dd/mmm hh:mm
ERROR LOG RESET
>Y<
N
DISPLAY MESSAGE
LOG MONITOR Exx aabb ddmmm
hh:mm
Exx = error (Exx) or warning (Wxx) code
aabb = Indicates "WHERE" the error has
occurred (S = instant product, C = coffee,
L = rinsing, e.g. S01 = instant product 01).
dd = day of the month
mmm = month
hh = hour
mm = minute
Use '+' and '-' to scroll the list.
Actually, the log will not be erased, the VM
will merely display the information stored
subsequent to this operation
The VM will once again display all
information.