Deciding on where to install the indoor unit
Indoor unit
There must be no obstacles near the air inlet and outlet.
Install the indoor unit on a ceiling that can support its weight.
Maintain sufficient clearance around the indoor unit.
Make sure that the water dripping from the drain hose runs away correctly
and safely.
The indoor unit must be installed in this way, that they are out of public
access. (Not touchable by the users)
CAUTION
As a rule, the unit cannot be installed at a height of less than 2.5 m.
It is possible to install the unit at a height of between 2.2~2.5m from
the ground, if the unit has a duct with a well defined length (300mm
or more) to avoid fan motor blower contact.
Space requirements for indoor unit
CAUTION
The units must be installed according to distances declared, in order to
permit accessibility from each side, either to guarantee correct operation
of maintenance or repairing products.
The unit's parts must be reachable and removable completely under safety
condition (for people or things).