Commencing operation
Instructions for assembly following transportation
CAUTION
HAZARD
6. Fit the suction pipe and drum control rod.
March 2013 Edition
Excessive belt tension may cause the premature failure of the ball bearings.
The drum belt must have a 10.5 mm stretch with a centre load of 30
be adjusted using the screw (pos. 7 fig. A photo 1) and the Allen nut marked with the
yellow arrow in photo 2.
The vacuum cleaner belt must have a 8 mm stretch with a centre load of 18
tension can be adjusted using the belt tightener.
1
2
Using the machine when not fully assembled may cause injury or damage to people or
objects. Do not use the machine when it is not fully assembled. Keep all fittings tightly
closed. Maintain machine settings in accordance with the specifications.
10
±
3N. Belt tension can
±
2N. The belt