Sharp AY-ZP35PR Service Manual page 41

Air/air heat pump
Table of Contents

Advertisement

AY-ZP35PR
Problem
Outdoor
symptom
unit indi-
cation
(LED1)
Indoor and
9-time
outdoor units
do not oper-
ate.
Indoor and
outdoor units
do not oper-
ate.
Indoor and
10-time
outdoor units
do not oper-
ate.
Indoor and
outdoor units
do not oper-
ate.
Indoor and
outdoor units
do not oper-
ate.
Indoor unit
Malfunc-
tion No.
Lamp
Main Sub
Timer (Orange)
9
0
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
4
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
10
0
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
1
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
2
Operation (Green)
Plasmacluster
(Blue)
Content of diagnosis
Main
Sub
Cycle tem-
Thermistor
perature
installation error
or 4-way valve
error.
4 way valve error
or Gas leak error
EEPROM
EEPROM (out-
error
door) data error
EEPROM (out-
door) data error
CPU (outdoor)
RAM data error
3-18
Check point
(1) Check the ther-
(1) Correct the instal-
mistor (heat
lation.
exchanger) and (2-
way valve) are
installed in correct
positions.
(2) Check resistance of
(2) Change the speci-
thermistors (heat
fied amount of
exchanger and 2-
refrigerant.
way valve).
(3) Check the 4-way
(3) Replace the 4-way
valve for proper
valve.
operation.
(4) No abnormality
(4) Replace the out-
found in above
door unit control
inspections (1)
PWB assembly.
through (3).
(1) Check the indoor/
(1) Correct the instal-
outdoor heat
lation.
exchanger ther-
mistors are installed
in correct positions.
(2) Check if the refriger-
(2) Change the speci-
ant volume is abnor-
fied amount of
mally low.
refrigerant.
(3) Check the 4-way
(3) Replace the 4-way
valve for proper
valve.
operation.
-
(1) Replace the out-
door unit control
PWB assembly.
Action