Sharp AY-ZP35PR Service Manual page 42

Air/air heat pump
Table of Contents

Advertisement

Problem
Outdoor
symptom
unit indi-
cation
(LED1)
Indoor and
11-time
outdoor units
do not oper-
ate.
Indoor and
12-time
outdoor units
do not oper-
ate.
Indoor unit
Malfunc-
tion No.
Lamp
Main Sub
Timer (Orange)
11
0
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
1
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
2
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
3
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
4
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
5
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
12
0
Operation (Green)
Plasmacluster
(Blue)
Content of diagnosis
Main
Sub
Outdoor unit
Outdoor unit DC
DC fan
fan rotation error
Outdoor unit DC
fan drive IC error
Outdoor unit DC
fan lock error
Detection error of
DC fan negative
rotation before
compressor is
driven
Detection error of
inverter current
for DC fan
Outdoor unit DC
fan open con-
nector error
Thermal
Thermal fuse
fuse in ter-
error in terminal
minal board
board (for power
supply)
3-19
Check point
(1) Check connector
(1) Correct the instal-
CN3 of the outdoor
lation.
unit DC fan motor for
secure installation.
(2) Check the outdoor
(2) Replace the out-
unit fan motor for
door unit fan
proper rotation.
motor.
(3) Check fuse FUSE5. (3) Replace the out-
door unit control
PWB assembly.
(4) No abnormality
(4) Replace the out-
found in above
door unit control
inspections (1)
PWB assembly.
through (3).
(1) Check if the fan IPM
(1) Replace the out-
terminal resistance
door unit control
values are uniform.
PWB assembly.
(2) Outdoor unit fan
(2) Replace the out-
motor continuity
door unit fan.
check.
(1) Check the outdoor
(1) Replace the out-
unit fan motor for
door unit control
proper rotation.
PWB assembly.
(2) (1):Normal
(2) Replace the out-
door unit fan.
(1) (Temporary stop for
DC fan circuit protec-
tion)
-
(1) Replace the out-
door unit control
PWB assembly.
(1) Check connector
(1) Correct the instal-
CN3 of the outdoor
lation.
unit DC fan motor for
secure installation.
(2) No abnormality
(2) Replace the out-
found in above
door unit control
inspections (1).
PWB assembly.
(1) Check the thermal
(1) Replace terminal
fuse in terminal
board for Power
board (for Power
supply
supply)
(2) Check connector
(2) Correct the instal-
CN5 of the outdoor
lation.
unit.
(3) No abnormality
(3) Replace the out-
found in above
door unit control
inspections (1) and
PWB assembly.
(2).
AY-ZP35PR
Action
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ay-zp40prAe-z35prAe-z40pr

Table of Contents