Chart - Sharp AY-ZP35PR Service Manual

Air/air heat pump
Table of Contents

Advertisement

[9] CHART

<INDOOR UNIT>
:1-second ON / 1-second OFF
Problem
Outdoor
symptom
unit indi-
cation
(LED1)
Normal con-
Normal
dition
blinking
Indoor and
1-time
outdoor units
do not oper-
ate.
Indoor and
2-time
outdoor units
do not oper-
ate.
Indoor unit
operates.
Outdoor unit
does not
operate tem-
porarily.
Indoor and
outdoor units
do not oper-
ate.
Indoor unit
Malfunc-
tion No.
Lamp
Main Sub
Timer (Orange)
0
0
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
1
0
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
1
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
2
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
3
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
2
0
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
1
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
2
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
3
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
4
Operation (Green)
Plasmacluster
(Blue)
Timer (Orange)
5
Operation (Green)
Plasmacluster
(Blue)
Content of diagnosis
Main
Sub
Normal
Outdoor unit
Heat exchanger
thermistor
thermistor short
short-circuit
circuit error
Outdoor temper-
ature thermistor
short circuit error
Suction ther-
mistor short cir-
cuit error
2-way valve
thermistor short
circuit error
Cycle tem-
Compressor high
perature
temperature
error
Compressor dis-
charge overheat.
Outdoor unit heat
exchanger over-
heat.
Indoor unit heat
exchanger over-
heat.
IPM high temper-
ature error
IPM high temper-
ature error
3-15
Check point
(1) Measure the resis-
(1) Replace the out-
tance of the outdoor
door unit ther-
unit thermistors.
mistor assembly.
(2) Check the lead wire
(2) Replace the out-
of the outdoor unit
door unit ther-
thermistor for torn
mistor assembly.
sheath and shortcir-
cuit.
(3) No abnormality
(3) Replace the out-
found in above
door unit control
inspections (1) and
PWB assembly.
(2).
(1) Check the outdoor
(1) Ensure unob-
unit air outlet for
structed air flow
blockage.
from the outdoor
unit air outlet.
(2) Check if the power
(2) Connect power
supply voltage is AC
supply of proper
230V at full power.
voltage.
(3) Check the pipe con-
(3) Charge the speci-
nections for refriger-
fied amount of
ant leaks.
refrigerant.
(4) Measure resistance
(4) Replace the out-
of the outdoor unit
door unit compres-
compressor ther-
sor thermistor
mistor.
assembly.
(5) Check the expansion
(5) Replace the
valve for proper
expansion valve
operation.
coil, expansion
valve or outdoor
unit control PWB
assembly.
(Temporary stop for cycle
protection)
(Temporary stop for cycle
protection)
(Temporary stop for cycle
protection)
(Temporary stop for cycle
protection)
(1) Measure resistance
(1) Replace the out-
of the heat-sink ther-
door unit PFCM
mistor.
PWB or control
PWB assembly or
change the heat-
sink thermistor.
AY-ZP35PR