Figure showing the Installation of Indoor and Outdoor Unit
!
CAUTION
In case the pipe length is more than 8m, add refrigerant R410A at 15 gram per every meter
exceeds. However, pipe length shall not exceed 15m.
Be sure to
completely
seal any gap.
– 5 –
The indoor piping should be
insulated with the enclosed
insulation pipe. (If the insulator
is insufficient, please use
commercial products).
The difference in height
between the indoor and
outdoor unit should be kept
max 10m.
The connecting pipe, no
matter big or small, should all
be insulated with insulation
pipe and then wrapped with
vinyl tape. (The insulator
will deteriorate if it is not
wrapped with tape).
The connection of insulated
drain hose.
Please use insulated drain
hose for the indoor piping
(commercial product).