BASIC MODE
MODEL RAS-18G5/RAC-18G5
Operation mode
No.
Control function
ON / OFF switch,
1
basic mode
OFF timer
Timer
2
operation
ON timer
Automatic
HI
Operation in "HI" mode
Fan speed
3
mode
MED
Operation in "MED" mode
G
LO
Operation in "LO" mode
G
Only circulation with cut velocity
G
is executed, independent of the
thermostat signal.
(1) Strong
Thermostat operation
H
HI
M
MED
L
LO
4
The power relay is
G
delayed by 2 seconds
from the start of
thermostat.
Cooling
"HI", "MED", or "LO" operation is executed
G
according to the thermostat signal. (Refer to
"Thermostat operation".)
Same as on the left.
G
G
Same as on the left.
G
Same as on the left.
G
(1) In case of "Automatic" mode
(1) When the set temperature is lower than the room temperature.
Notes:
G
G
Note:
The min. ON time of the power relay is 3
G
(2) Set temperature is higher than room temperature.
minutes, and the min. OFF time also is
3 minutes.
(2) In other modes than "Automatic"
Same as above (but operation is made
with the velocity set at the time of operation
start).
Sensor dehumidi cation
"LO" and "Stop" are repeated according to the thermostat signal, independent
of the setting.
The min. ON time of the power relay is 3 minutes, and the min. OFF time
also is 3 minutes.
The indoor fan is not delayed with operation start by ON / OFF button.
Notes:
Forced operation by ON / OFF
G
button ON is executed even
with thermostat OFF.
The room temperature 30 sec
G
after operation start, minus
0.66 deg, becomes the set
temperature.
When the room temperature
G
is 16°C or lower, 16°C
becomes the set temperature.
The other operations are the
G
same as for (1).
Circulation
Both operation lamp during Sensor dehumidi cation at
operation mode.
Repetition of "HI" and "Stop" by means of thermo signal and time.
G
Repetition of "MED" "Stop" by means of thermo signal and time.
G
Repetition of "LO" "Stop" by means of thermo signal and time.
G
– 37 –