o
One 90
elbow = Two 45
Option
V
H + H1
A)
0' Min.
2' Max.
B)
1' Min.
3' Max.
C)
2' Min.
4' Max.
D)
3' Min.
5' Max.
E)
4' Min.
6' Max.
F)
5' Min.
7' Max.
G)
6' Min.
8' Max.
Lengths do not include
elbow indicated
o
One 90
Option
V
H
A)
0' Min.
1' Max.
B)
1' Min.
2' Max.
C)
2' Min.
2' Max.
D)
3' Min.
2' Max.
E)
4' Min.
3 Max.
F)
5' Min.
4' Max. 10' Min. 7' Max.
G)
6' Min.
5' Max. 11' Min. 8' Max.
H)
7' Min.
6' Max. 12' Min. 9' Max.
Lengths do not include elbow indicated
FPI P36-4 Zero Clearance Direct Vent Gas Fireplace
Horizontal Venting with Two (2) 90
o
elbows.
W i t h t h e s e o p t i o n s ,
maximum total pipe length
is 30 feet with minimum
of 6 feet total vertical
and maximum 8 feet total
horizontal.
Please note minimum 1
foot between 90
o
elbows
is required.
Horizontal Venting with Three (3) 90
o
elbow = Two 45
elbows.
V + V1
H + H1
With these options,
1' Min.
2' Max.
max. total pipe
3' Min.
3' Max.
length is 30 feet
with min. of 12 feet
5' Min.
4' Max.
total vertical and
7' Min.
5' Max.
max. 9 feet total
horizontal.
9' Min.
6' Max.
Please note min. 1
foot between 90
elbows is required.
o
Elbows
H1
o
Elbows
o
INSTALLATION
V
25