4.5 Error Log
Error Code
#1104
Basic shelf heat alarm
#1105
Expansion shelf 1 heat
alarm
#1106
Expansion shelf 2 heat
alarm
#1107
Basic shelf fan alarm
#1108
Expansion shelf 1 fan alarm The fan of Expansion shelf 1 gets out of order.
#1109
Expansion shelf 2 fan alarm The fan of Expansion shelf 2 gets out of order.
#1110
Calendar IC R/W stop
#1111
Calendar IC stop
#1112
CPU RAM battery alarm
Error Log (Minor)
Error Code
#1200
Basic shelf AC power down The Basic shelf AC power malfunction occurs for the
#1201
Expansion shelf 1 AC
power down
#1202
Expansion shelf 2 AC
power down
254
Error Message
Error Message
The heat of the power supply of Basic shelf exceeds the
limit.
The heat of the power supply of Expansion shelf 1
exceeds the limit.
The heat of the power supply of Expansion shelf 2
exceeds the limit.
The fan of Basic shelf gets out of order.
The calendar IC of CPU card is defective.
The calendar IC of CPU card is defective.
The CPU RAM battery alarm occurs because of defective
lithium battery on the CPU card or defective CPU card.
following reasons.
a)
AC power cord is unplugged.
b)
Power Failure
c)
Malfunction of Power Supply Unit of the Basic
Shelf or the trouble with the Power Supply System
(Backboard, CPU card) of the Shelf
The Expansion shelf AC power malfunction occurs for
the following reasons.
a)
Power Failure
b)
Malfunction of Power Supply Unit of the
Expansion Shelf 1, or the trouble with the Power
Supply System (Backboard, CPU card) of the
Shelf
The Expansion shelf AC power malfunction occurs for
the following reasons.
a)
Power Failure
b)
Malfunction of Power Supply Unit of the
Expansion Shelf 2, or the trouble with the Power
Supply System (Backboard, CPU card) of the
Shelf
Cause