5.1.3 Operation

PROBLEM
• When using the
speakerphone mode with a
proprietary telephone KX-
T7130 or KX-T7030,
nothing is audible.
• When using the
speakerphone/monitor
mode with a DPT, nothing
is audible.
The unit does not ring.
During a power failure,
extensions assigned for power
failure operation do not
operate.
Originating an outside call,
Call Transfer, or Conference
cannot be performed.
Troubleshooting
PROBABLE CAUSE
• The HANDSET /
HEADSET selector of the
KX-T7130 or KX-T7030
is set to the "HEADSET"
position.
• The "HEADSET" mode
is selected by Station
Programming, "Handset/
Headset Selection."
The Ringer Volume Selector
is set to "OFF."
• A DPT or APT is
connected to the
extension port.
• The dialling mode (tone
or pulse) is improper.
The corresponding CO
button does not exist on the
proprietary telephone.
POSSIBLE SOLUTION
• When the headset is not used, set the
HANDSET / HEADSET selector to
the "HANDSET" position.
• When the headset is not used, select
the "HANDSET" mode by Station
Programming.
Set to "HIGH" or "LOW."
• Disconnect the DPT or APT and
connect a single line telephone.
• Set the Tone / Pulse switch to the
other position.
Programme the CO button. See
"Flexible CO key Assignment" in
Section 4.3 Extension Line of the
Programming Guide.